OSHA SearchOSHA records by employer

MK Kitchen and Bath LLC: OSHA inspections and violations

Washington, District of Columbia · Residential Remodelers · NAICS 236118

1inspections
10citation items
$12,500current penalties
Apr 20, 2018last inspection

OSHA inspectors have visited MK Kitchen and Bath LLC in District of Columbia one time.

It opened on Apr 20, 2018 as a planned inspection, in Washington.

In all, OSHA issued 10 citation items: 7 serious and 3 other-than-serious.

The proposed penalties came to $29,378; today they stand at $12,500, 57% less.

The rule cited most here is 1926.1053 (ladders in construction), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. MK Kitchen and Bath LLC averages $12,500 across 1 cited inspection.

MK Kitchen and Bath LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

District of Columbia · latest 90 days of OSHA records

14employers cited

Get notified the morning OSHA posts each new citation in District of Columbia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in District of Columbia

Checking a subcontractor, a client or your own company? Watch MK Kitchen and Bath LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343104444 OPENED APR 20, 2018Closed

Planned · Partial · Safety · 8 employees at the site · Closed Feb 10, 2022

1714 A Street Se, Washington, DC 20003 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$3,880$1,425Oct 18, 2018Final
Citation 1, item 2
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$3,880$1,425Oct 18, 2018Final
Citation 1, item 3
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$2,772$1,200Oct 18, 2018Final
Citation 1, item 4
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$3,880$1,425Oct 18, 2018Final
Citation 1, item 5
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,880$1,425Oct 18, 2018Final
Citation 1, item 6
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$5,543$2,800Oct 18, 2018Final
Citation 1, item 7
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$5,543$2,800Oct 18, 2018Final
Citation 2, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Oct 18, 2018Final
Citation 2, item 2
29 CFR 1926.1053(b)(15) · Ladders in construction
Other-than-serious$0$0Oct 18, 2018Final
Citation 2, item 3
29 CFR 1926.1053(b)(16) · Ladders in construction
Other-than-serious$0$0Oct 18, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(13)

(13) The top or top step of a stepladder shall not be used as a step.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other residential remodelers employers in District of Columbia

Alert subscribers get notified of each newly cited employer in District of Columbia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.