OSHA SearchOSHA records by employer

MMC Specialty Roofing Company, Inc: OSHA inspections and violations

Vernon, Connecticut · Roofing Contractors · NAICS 238160

2inspections
3citation items
$2,439current penalties
Jan 12, 2022last inspection

Since 2018, OSHA inspectors have visited MMC Specialty Roofing Company, Inc in Connecticut 2 times.

The most recent inspection opened on Jan 12, 2022 as a planned inspection, in Newington.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $4,878; today they stand at $2,439, 50% less.

The rule cited most here is 1926.502 (fall protection systems), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. MMC Specialty Roofing Company, Inc averages $2,439 across 1 cited inspection.

MMC Specialty Roofing Company, Inc: OSHA citation items per year, 2018 to 2022
Citation items per year, by inspection date.

Connecticut · latest 90 days of OSHA records

86employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Connecticut

Checking a subcontractor, a client or your own company? Watch MMC Specialty Roofing Company, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345739858 OPENED JAN 12, 2022Closed

Planned · Partial · Safety · 15 employees at the site · Closed Jan 12, 2022

2530 Berlin Turnpike, Newington, CT 06111 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343293395 OPENED JUL 11, 2018Closed

Planned · Partial · Safety · 9 employees at the site · Closed Aug 2, 2018

16 Vernon Avenue, Vernon, CT 06066 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Serious$1,829$914Jul 13, 2018Final
Citation 1, item 2a
29 CFR 1926.502(f)(1) · Fall protection systems
Serious$3,049$1,524Jul 13, 2018Final
Citation 1, item 2b
29 CFR 1926.502(f)(1)(ii) · Fall protection systems
Serious$0$0Jul 13, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.502(f)(1)

(1) The warning line shall be erected around all sides of the roof work area.

29 CFR 1926.502(f)(1)(ii)

(ii) When mechanical equipment is being used, the warning line shall be erected not less than 6 feet (1.8 m) from the roof edge which is parallel to the direction of mechanical equipment operation, and not less than 10 feet (3.1 m) from the roof edge which is perpendicular to the direction of mechanical equipment operation.