OSHA SearchOSHA records by employer

Mobilight International, Inc: OSHA inspections and violations

Tooele, Utah · Truck Trailer Manufacturing · NAICS 336212

1inspections
4citation items
$0current penalties
Jan 30, 2024last inspection

Mobilight International, Inc has one OSHA inspection on record in Utah.

OSHA opened it on Jan 30, 2024 after a complaint, in Tooele.

From that inspection OSHA issued 4 citation items: 4 other-than-serious.

OSHA did not attach a penalty to any of these citations.

Most often, OSHA cited 1910.157, portable fire extinguishers (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Mobilight International, Inc averages $0 over 1 cited inspection in that time.

Mobilight International, Inc: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

67employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Mobilight International, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347242968 OPENED JAN 30, 2024Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Apr 24, 2024

1729 South Main Street, Tooele, UT 84074 · Truck Trailer Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1a
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Mar 13, 2024Final
Citation 2, item 1b
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Mar 13, 2024Final
Citation 2, item 2
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Mar 13, 2024Final
Citation 2, item 3
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Mar 13, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(c)(1)

(c) General requirements. (1) The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.

29 CFR 1910.157(e)(3)

(3) The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(1)

(1) Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.

29 CFR 1910.305 · Electrical wiring methods

Other truck trailer manufacturing employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.