OSHA SearchOSHA records by employer

Molloy Corporation: OSHA inspections and violations

Houston, Texas · Commercial Printing (except Screen and Books) · NAICS 323111

1inspections
2citation items
$1,454current penalties
Sep 19, 2016last inspection

OSHA has inspected Molloy Corporation once in Texas.

The inspection began on Sep 19, 2016 after a complaint, in Houston.

That inspection ended with 2 citation items: 1 serious and 1 other-than-serious.

Penalties were first proposed at $2,423 and now stand at $1,454, 40% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Molloy Corporation averages $1,454 (1 cited inspection).

Molloy Corporation: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Molloy Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341780153 OPENED SEP 19, 2016Closed

Complaint · Partial · Health · 22 employees at the site · Closed Mar 28, 2017

9000 Southwest Freeway, Ste. 320, Houston, TX 77074 · Commercial Printing (except Screen and Books) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Serious$2,423$1,454Dec 30, 2016Final
Citation 2, item 1
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Other-than-serious$0$0Dec 30, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(d)(1)(iii)

(iii) The employer shall identify and evaluate the respiratory hazard(s) in the workplace; this evaluation shall include a reasonable estimate of employee exposures to respiratory hazard(s) and an identification of the contaminant's chemical state and physical form. Where the employer cannot identify or reasonably estimate the employee exposure, the employer shall consider the atmosphere to be IDLH.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(1)

(1) Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.

Other commercial printing (except screen and books) employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.