Inspection 346152747 OPENED AUG 12, 2022Closed
3901 Mesa School Road, Somis, CA 93066 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Los Alamitos, California · Commercial and Institutional Building Construction · NAICS 236220
OSHA has inspected Monet Construction, Inc. 2 times in California since 2015.
The latest one began on Aug 12, 2022 as part of a related case, in Somis.
Those inspections ended with 4 citation items: 4 serious.
Penalties were first proposed at $6,300 and now stand at $3,150, 50% lower after settlements or reviews.
Electrical equipment on job sites comes up most often in these citations: 2 items under 1926.403.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Monet Construction, Inc. averages $3,150 (1 cited inspection).
Want to know if OSHA cites Monet Construction, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company3901 Mesa School Road, Somis, CA 93066 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Building 6 Jftb Los Alamitos, Los Alamitos, CA 90720 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.134(c)(2)(i) · Respiratory protection |
Serious | $2,100 | $1,050 | Jun 2, 2015 | Final |
| Citation 1, item 1b 29 CFR 1910.134(c)(2)(ii) · Respiratory protection |
Serious | $0 | $0 | Jun 2, 2015 | Final |
| Citation 1, item 2 29 CFR 1926.403(b)(1) · Electrical equipment on job sites |
Serious | $2,100 | $1,050 | Jun 2, 2015 | Final |
| Citation 1, item 3 29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites |
Serious | $2,100 | $1,050 | Jun 2, 2015 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.134(c)(2)(i)
(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and
29 CFR 1910.134(c)(2)(ii)
(ii) In addition, the employer must establish and implement those elements of a written respiratory protection program necessary to ensure that any employee using a respirator voluntarily is medically able to use that respirator, and that the respirator is cleaned, stored, and maintained so that its use does not present a health hazard to the user. Exception: Employers are not required to include in a written respiratory protection program those employees whose only use of respirators involves the voluntary use of filtering facepieces (dust masks).
29 CFR 1926.403(b)(1)
(b) Examination, installation, and use of equipment—(1) Examination. The employer shall ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined on the basis of the following considerations:
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.