OSHA SearchOSHA records by employer

Monro Muffler and Brake Inc.: OSHA inspections and violations

Seven Hills, Ohio · General Automotive Repair · NAICS 811111

1inspections
2citation items
$10,050current penalties
Dec 4, 2025last inspection

OSHA has inspected Monro Muffler and Brake Inc. once in Ohio.

The inspection began on Dec 4, 2025 after a complaint, in Seven Hills.

That inspection ended with 2 citation items: 2 serious.

Penalties were first proposed at $10,050 and still stand at $10,050.

Gas welding and cutting comes up most often in these citations: 2 items under 1910.253.

How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and Monro Muffler and Brake Inc. averages $10,050 (1 cited inspection).

Monro Muffler and Brake Inc.: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

257employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Monro Muffler and Brake Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348626516 OPENED DEC 4, 2025Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Apr 13, 2026

7801 Broadview Road, Seven Hills, OH 44131 · General Automotive Repair · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Serious$10,050$10,050Feb 4, 2026Final
Citation 1, item 1b
29 CFR 1910.253(b)(4)(i) · Gas welding and cutting
Serious$0$0Feb 4, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.253(b)(2)(ii)

(ii) Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards.

29 CFR 1910.253(b)(4)(i)

(4) Oxygen storage. (i) Oxygen cylinders shall not be stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near any other substance likely to cause or accelerate fire; or in an acetylene generator compartment.

Other general automotive repair employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.