OSHA SearchOSHA records by employer

Monro Muffler and Brakes, Inc.: OSHA inspections and violations

Whitehall, Pennsylvania · General Automotive Repair · NAICS 811111

1inspections
9citation items
$23,000current penalties
Nov 8, 2017last inspection

OSHA inspectors have visited Monro Muffler and Brakes, Inc. in Pennsylvania one time.

It opened on Nov 8, 2017 after a complaint, in Whitehall.

In all, OSHA issued 9 citation items: 5 serious and 4 other-than-serious.

The proposed penalties came to $32,593; today they stand at $23,000, 29% less.

The rule cited most here is 1910.252 (welding fire safety), 2 times.

Among repair and personal services employers, the typical cited inspection since 2015 ends with a $1,200 penalty. Monro Muffler and Brakes, Inc. averages $23,000 across 1 cited inspection.

Monro Muffler and Brakes, Inc.: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

277employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Monro Muffler and Brakes, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342759255 OPENED NOV 8, 2017Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Jan 24, 2018

1326 Grape Street, Whitehall, PA 18052 · General Automotive Repair · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.151(c) · First aid and eyewash
Serious$7,243$6,973Nov 27, 2017Final
Citation 1, item 2a
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$9,054$9,054Nov 27, 2017Final
Citation 1, item 2b
29 CFR 1910.252(a)(2)(iii)(a) · Welding fire safety
Serious$0$0Nov 27, 2017Final
Citation 1, item 6a
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$5,432$6,973Nov 27, 2017Final
Citation 1, item 6b
29 CFR 1910.334(a)(3)(ii) · Using electrical equipment
Serious$5,432$0Nov 27, 2017Final
Citation 2, item 1
29 CFR 1910.28(b)(3)(ii) · Fall protection in general industry
Other-than-serious$0$0Nov 27, 2017Final
Citation 2, item 2
29 CFR 1910.135(a)(1) · Head protection
Other-than-serious$0$0Nov 27, 2017Final
Citation 2, item 3c
29 CFR 1910.253(e)(6)(ii) · Gas welding and cutting
Other-than-serious$0$0Nov 27, 2017Final
Citation 2, item 4
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$5,432$0Nov 27, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.135 · Head protection

29 CFR 1910.135(a)(1)

(a) General requirements. (1) The employer shall ensure that each affected employee wears a protective helmet when working in areas where there is a potential for injury to the head from falling objects.

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.151(c)

(c) Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

Other general automotive repair employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.