Monterey-Fire Department: OSHA inspections and violations

Monterey, Tennessee · Fire Protection · NAICS 922160

1inspections
3citation items
$0current penalties
Sep 30, 2015last inspection

OSHA has inspected Monterey-Fire Department once in Tennessee.

The inspection began on Sep 30, 2015 as a planned inspection, in Monterey.

That inspection ended with 3 citation items: 3 serious.

None of the citations carried a penalty.

How that compares: the median penalty per cited inspection for public administration employers since 2015 is $0, and Monterey-Fire Department averages $0 (1 cited inspection).

Monterey-Fire Department: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

339employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Monterey-Fire Department and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340958131 OPENED SEP 30, 2015Closed

Planned · Complete · Safety · Local government · 10 employees at the site · Closed Nov 16, 2015

401 North Elmore Street, Monterey, TN 38574 · Fire Protection · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Oct 26, 2015Final
Citation 1, item 2
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Serious$0$0Oct 26, 2015Final
Citation 1, item 3
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Serious$0$0Oct 26, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(6)(ii)

(ii) Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(f)(2)

(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.334(a)(2)(i)

(2) Visual inspection. (i) Portable cord- and plug-connected equipment and flexible cord sets (extension cords) shall be visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord- and plug-connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated.

Other fire protection employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.