OSHA SearchOSHA records by employer

Monterey - Waste Water Plant: OSHA inspections and violations

Monterey, Tennessee · Sewage Treatment Facilities · NAICS 221320

2inspections
13citation items
$0current penalties
Sep 15, 2026last inspection

Since 2021, OSHA inspectors have visited Monterey - Waste Water Plant in Tennessee 2 times.

The most recent inspection opened on Sep 15, 2026 as a planned inspection, in Monterey.

In all, OSHA issued 13 citation items: 13 serious.

No penalty came with these citations.

The rule cited most here is 1910.1200 (hazard communication), 4 times.

Among utility employers, the typical cited inspection since 2015 ends with a $0 penalty. Monterey - Waste Water Plant averages $0 across 2 cited inspections.

Monterey - Waste Water Plant: OSHA citation items per year, 2021 to 2026
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

335employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Monterey - Waste Water Plant and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 349171306 OPENED SEP 15, 2026Closed

Planned · Complete · Safety · Local government · 2 employees at the site · Closed Oct 7, 2026

314 West Stewart Street, Monterey, TN 38574 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Sep 24, 2026Final
Citation 1, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$0$0Sep 24, 2026Final
Citation 1, item 3
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$0$0Sep 24, 2026Final
Citation 1, item 4
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$0$0Sep 24, 2026Final
Citation 1, item 5
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Serious$0$0Sep 24, 2026Final
Citation 1, item 6
29 CFR TDLWD RULE 800-01-09-.07
Serious$0$0Sep 24, 2026Final

Inspection 345236061 OPENED APR 6, 2021Closed

Planned · Complete · Safety · Local government · 2 employees at the site · Closed Aug 16, 2021

13785 Woodcliff Road, Monterey, TN 38574 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(2)(ii) · Flammable liquids
Serious$0$0Apr 23, 2021Final
Citation 1, item 2
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Serious$0$0Apr 23, 2021Final
Citation 1, item 3
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Apr 23, 2021Final
Citation 1, item 4
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Apr 23, 2021Final
Citation 1, item 5
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$0$0Apr 23, 2021Final
Citation 1, item 6
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Serious$0$0Apr 23, 2021Final
Citation 1, item 7
29 CFR TDLWD RULE 800-01-09-.07
Serious$0$0Apr 23, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(2)(ii)

(ii) Containers. Flammable liquids shall be stored in tanks or closed containers.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(f)(6)(ii)

(ii) Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other sewage treatment facilities employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.