4inspections
13citation items
$0current penalties
Dec 21, 2018last inspection

OSHA has inspected Mooers TN. HWY. Dept. 4 times in New York since 2018.

The latest one began on Dec 21, 2018 to follow up on an earlier case, in Mooers.

Those inspections ended with 13 citation items: 12 serious and 1 other-than-serious.

None of the citations carried a penalty.

Flammable liquids comes up most often in these citations: 3 items under 1910.106.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Mooers TN. HWY. Dept. averages $0 (1 cited inspection).

Mooers TN. HWY. Dept.: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

372employers cited

22 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Mooers TN. HWY. Dept. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343680757 OPENED DEC 21, 2018Closed

Follow-up · Partial · Safety · Local government · 6 employees at the site · Closed May 3, 2019

72 Missile Base Rd., Mooers, NY 12958 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343629002 OPENED NOV 30, 2018Closed

Follow-up · Partial · Safety · Local government · 6 employees at the site · Closed May 3, 2019

72 Missile Base Rd., Mooers, NY 12958 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343416996 OPENED AUG 22, 2018Closed

Monitoring · Partial · Safety · Local government · 6 employees at the site · Closed Dec 28, 2018

72 Missile Base Rd., Mooers, NY 12958 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342954138 OPENED FEB 15, 2018Closed

Planned · Complete · Safety · Local government · 6 employees at the site · Closed Feb 8, 2019

72 Missile Base Rd., Mooers, NY 12958 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(a)(3) · Exit routes
Serious$0$0Jun 20, 2018Final
Citation 1, item 2
29 CFR 1910.106(g)(1)(iii)(a) · Flammable liquids
Serious$0$0Jun 20, 2018Final
Citation 1, item 3
29 CFR 1910.106(g)(1)(iii)(c) · Flammable liquids
Serious$0$0Jun 20, 2018Final
Citation 1, item 4
29 CFR 1910.106(g)(3)(iii) · Flammable liquids
Serious$0$0Jun 20, 2018Final
Citation 1, item 5
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$0$0Jun 20, 2018Final
Citation 1, item 6
29 CFR 1910.151(c) · First aid and eyewash
Serious$0$0Jun 20, 2018Final
Citation 1, item 7
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Serious$0$0Jun 20, 2018Final
Citation 1, item 8
29 CFR 1910.244(a)(1)(ii) · Other portable tools and equipment
Serious$0$0Jun 20, 2018Final
Citation 1, item 9
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Jun 20, 2018Final
Citation 1, item 10
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$0$0Jun 20, 2018Final
Citation 1, item 11
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$0$0Jun 20, 2018Final
Citation 1, item 12
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$0$0Jun 20, 2018Final
Citation 2, item 1
29 CFR 12 NYCRR PART 801.29(A)
Other-than-serious$0$0Jun 20, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(g)(1)(iii)(a)

(iii) Inside buildings. (a) Except where stored in tanks as provided in paragraph (g)(1)(ii) of this section, no Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be stored within any service station building except in closed containers of aggregate capacity not exceeding 60 gallons. One container not exceeding 60 gallons capacity equipped with an approved pump is permitted.

29 CFR 1910.106(g)(1)(iii)(c)

(iii) Inside buildings. (a) Except where stored in tanks as provided in paragraph (g)(1)(ii) of this section, no Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be stored within any service station building except in closed containers of aggregate capacity not exceeding 60 gallons. One container not exceeding 60 gallons capacity equipped with an approved pump is permitted.

29 CFR 1910.106(g)(3)(iii)

(iii) Emergency power cutoff. A clearly identified and easily accessible switch(es) or a circuit breaker(s) shall be provided at a location remote from dispensing devices, including remote pumping systems, to shut off the power to all dispensing devices in the event of an emergency.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.244 · Other portable tools and equipment

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods