OSHA SearchOSHA records by employer

Morales Brick Layers: OSHA inspections and violations

Edmond, Oklahoma · Masonry Contractors · NAICS 238140

2inspections
6citation items
$5,365current penalties
Nov 9, 2023last inspection

OSHA has inspected Morales Brick Layers 2 times in Oklahoma since 2016.

The latest one began on Nov 9, 2023 as a planned inspection, in Oklahoma City.

Those inspections ended with 6 citation items: 5 serious and 1 other-than-serious.

Penalties were first proposed at $9,812 and now stand at $5,365, 45% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 5 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Morales Brick Layers averages $2,682 (2 cited inspections).

Morales Brick Layers: OSHA citation items per year, 2016 to 2023
Citation items per year, by inspection date.

Oklahoma · latest 90 days of OSHA records

58employers cited

Get notified the morning OSHA posts each new citation in Oklahoma: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oklahoma

Checking a subcontractor, a client or your own company? Watch Morales Brick Layers and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347096497 OPENED NOV 9, 2023Closed

Planned · Partial · Safety · 5 employees at the site · Closed Dec 10, 2024

16301 Iron Stone Pl, Oklahoma City, OK 73103 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,351$1,175Apr 29, 2024Final
Citation 1, item 1b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Apr 29, 2024Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,351$1,175Apr 29, 2024Final

Inspection 341616134 OPENED JUL 7, 2016Closed

Planned · Partial · Health · 10 employees at the site · Closed Jan 10, 2018

909 W. I-35 And Frontage Road, Edmond, OK 73034 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2)(v) · Scaffolds, general requirements
Serious$2,138$1,261Dec 9, 2016Final
Citation 1, item 2
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,672$1,576Dec 9, 2016Final
Citation 2, item 1
29 CFR 1926.602(d) · Earthmovers and forklifts in construction
Other-than-serious$300$177Dec 9, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)(v)

(v) Fork-lifts shall not be used to support scaffold platforms unless the entire platform is attached to the fork and the fork-lift is not moved horizontally while the platform is occupied.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.602 · Earthmovers and forklifts in construction

Other masonry contractors employers in Oklahoma

Alert subscribers get notified of each newly cited employer in Oklahoma the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.