OSHA SearchOSHA records by employer

Morgan Olson, LLC.: OSHA inspections and violations

Loudon, Tennessee · Motor Vehicle Body Manufacturing · NAICS 336211

3inspections
16citation items
$15,500current penalties
Mar 13, 2020last inspection

Since 2017, OSHA inspectors have visited Morgan Olson, LLC. in Tennessee 3 times.

The most recent inspection opened on Mar 13, 2020 after a complaint, in Loudon.

In all, OSHA issued 16 citation items: 5 serious and 11 other-than-serious.

The proposed penalties came to $18,400; today they stand at $15,500, 16% less.

The rule cited most here is 1910.305 (electrical wiring methods), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Morgan Olson, LLC. averages $5,167 across 3 cited inspections.

Morgan Olson, LLC. also files yearly injury logs with OSHA, summarized below.

Morgan Olson, LLC.: OSHA citation items per year, 2017 to 2020
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

353employers cited

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Morgan Olson, LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344717533 OPENED MAR 13, 2020Closed

Complaint · Partial · Safety · 1,200 employees at the site · Closed Sep 18, 2020

9600 Corporate Dr, Loudon, TN 37774 · Motor Vehicle Body Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR TCA 50-3-105(1)
Serious$5,000$5,000Jul 7, 2020Final

Inspection 344288998 OPENED SEP 6, 2019Closed

Complaint · Partial · Health · 600 employees at the site · Closed Nov 19, 2019

9600 Corporate Park Dr., Loudon, TN 37774 · Motor Vehicle Body Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1020(e)(2)(ii)(a) · Access to employee exposure and medical records
Other-than-serious$800$800Oct 25, 2019Final
Citation 1, item 2
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Other-than-serious$200$200Oct 25, 2019Final
Citation 1, item 3
29 CFR TDLWD RULE 800-01-03-.03(27)(B)1
Other-than-serious$800$800Oct 25, 2019Final

Inspection 342107760 OPENED FEB 15, 2017Closed

Referral · Partial · Safety · 316 employees at the site · Closed Jun 12, 2017

9600 Corporate Park Dr., Loudon, TN 37774 · Motor Vehicle Body Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Feb 8, 2017: Employee's finger is amputated when caught in press die

At 9:30 a.m. on February 8, 2017, Employee #1 was operating a 7036 Truebend Brake Press, performing bend operations on a part. The employee had completed 76 of the 78 pieces needed. As he proceeded to the next piece, his middle finger became caught between the piece being bent and the outer section of the upper die of the press, amputating it.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR TCA 50-3-105(1)
Serious$2,400$2,000Apr 7, 2017Final
Citation 1, item 2a
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$2,800$2,400Apr 7, 2017Final
Citation 1, item 2b
29 CFR 1910.106(d)(4)(iii) · Flammable liquids
Serious$0$0Apr 7, 2017Final
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$4,000$3,000Apr 7, 2017Final
Citation 2, item 1
29 CFR 1910.133(a)(1) · Eye and face protection
Other-than-serious$400$200Apr 7, 2017Final
Citation 2, item 2
29 CFR 1910.138(a) · Gloves and hand protection
Other-than-serious$400$200Apr 7, 2017Final
Citation 2, item 3
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Other-than-serious$200$100Apr 7, 2017Final
Citation 2, item 4
29 CFR 1910.151(b) · First aid and eyewash
Other-than-serious$600$200Apr 7, 2017Final
Citation 2, item 5
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$400$200Apr 7, 2017Final
Citation 2, item 6a
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$200$200Apr 7, 2017Final
Citation 2, item 6b
29 CFR 1910.305(g)(1)(iv)(c) · Electrical wiring methods
Other-than-serious$0$0Apr 7, 2017Final
Citation 2, item 7
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$200$200Apr 7, 2017Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Loudon site logged 1 recordable injury or illness among about 126 workers: 0.8 per 100 full-time workers, against a median of 5.2 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Morgan Olson LLC Loudon
Loudon · 2025
126 100.85.2
Morgan Olson
Loudon · 2022
478 1142.45.2
Morgan Olson Loudon
Loudon · 2016
288 2917.95.2

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1020 · Access to employee exposure and medical records

29 CFR 1910.1020(e)(2)(ii)(a)

(ii) Employee medical records. (A) Each employer shall, upon request, assure the access of each employee to employee medical records of which the employee is the subject, except as provided in paragraph (e)(2)(ii)(D) of this section.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iii)

(iii) Wiring. Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be approved under subpart S of this part for Class I, Division 2 Hazardous Locations; for Category 3 flammable liquids with a flashpoint at or above 100 °F (37.8 °C) and Category 4 flammable liquids, shall be approved for general use.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.138 · Gloves and hand protection

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.305 · Electrical wiring methods

Other motor vehicle body manufacturing employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.