OSHA SearchOSHA records by employer

Morris Coupling Company: OSHA inspections and violations

Knoxville, Tennessee · Fabricated Pipe and Pipe Fitting Manufacturing · NAICS 332996

6inspections
15citation items
$4,615current penalties
Feb 19, 2026last inspection

Morris Coupling Company has 6 OSHA inspections on record in Tennessee, the first in 1994.

OSHA's last visit started on Feb 19, 2026 as a planned inspection, in Knoxville.

Across those inspections OSHA issued 15 citation items: 6 serious and 9 other-than-serious.

OSHA proposed $4,615 in penalties and the amount has not been reduced.

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Morris Coupling Company averages $3,625 over 1 cited inspection in that time.

Morris Coupling Company also files yearly injury logs with OSHA, summarized below.

Morris Coupling Company: OSHA citation items per year, 1994 to 2026
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

334employers cited

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Morris Coupling Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Morris Coupling Company at 2 sites in 2 states. Together they've had 13 inspections and $17,818 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 2 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 348761602 OPENED FEB 19, 2026Closed

Planned · Complete · Safety · 32 employees at the site · Closed Apr 16, 2026

5112 N. National Drive, Knoxville, TN 37914 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,750$1,750Mar 26, 2026Final
Citation 1, item 2
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$1,750$1,750Mar 26, 2026Final
Citation 2, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$125$125Mar 26, 2026Final

Inspection 306774811 OPENED JUN 27, 2003Closed

Planned · Complete · Health · 55 employees at the site · Closed Aug 13, 2003

5112 North National Drive, Knoxville, TN 37914 · Fabricated Pipe and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 90007
Serious$240$240Jul 16, 2003Closed

Inspection 303497069 OPENED MAR 16, 2000Closed

Planned · Complete · Safety · 60 employees at the site · Closed Jun 6, 2000

5320 South National Drive, Knoxville, TN 37914 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 90007
Other-than-serious$0$0May 5, 2000Closed

Inspection 127331247 OPENED NOV 6, 1997Closed

Planned · Complete · Safety · 55 employees at the site · Closed Mar 10, 1998

5320 South National Drive, Knoxville, TN 37914 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.243(c)(1) · Guarding of portable powered tools
Serious$250$250Feb 4, 1998Closed
Citation 2, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Other-than-serious$0$0Feb 4, 1998Closed
Citation 2, item 2
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Other-than-serious$0$0Feb 4, 1998Closed
Citation 2, item 3
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Feb 4, 1998Closed

Inspection 120516596 OPENED SEP 29, 1995Closed

Complaint · Partial · Health · 74 employees at the site · Closed Feb 16, 1996

5320 South National Drive, Knoxville, TN 37914 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$100$100Nov 14, 1995Closed
Citation 1, item 2
29 CFR 9000609
Other-than-serious$0$0Nov 14, 1995Closed
Citation 1, item 3
29 CFR 9000704 A
Other-than-serious$100$100Nov 14, 1995Closed

Inspection 120540430 OPENED NOV 18, 1994Closed

Planned · Complete · Safety · 65 employees at the site · Closed Feb 15, 1995

5320 South National Drive, Knoxville, TN 37914 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$150$150Nov 30, 1994Closed
Citation 1, item 2
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$150$150Nov 30, 1994Closed
Citation 2, item 1
29 CFR 90007
Other-than-serious$0$0Nov 30, 1994Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Knoxville site logged 1 recordable injury or illness among about 69 workers: 1.4 per 100 full-time workers, against a median of 2.4 for its industry. Those cases cost 137 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Tennessee Tube Bending
Knoxville · 2025
69 111.42.4

Included with any plan: 7 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(d)(2)

(2) The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(1)

(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other fabricated pipe and pipe fitting manufacturing employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.