OSHA SearchOSHA records by employer

Morrison Engineers, PLLC: OSHA inspections and violations

Durham, North Carolina · Commercial and Institutional Building Construction · NAICS 236220

2inspections
3citation items
$1,820current penalties
Feb 12, 2020last inspection

OSHA has inspected Morrison Engineers, PLLC 2 times in North Carolina since 2010.

The latest one began on Feb 12, 2020 as part of a related case, in Cary.

Those inspections ended with 3 citation items: 1 serious and 2 other-than-serious.

Penalties were first proposed at $2,800 and now stand at $1,820, 35% lower after settlements or reviews.

Concrete and Masonry Construction: general requirements comes up most often in these citations: 2 items under 1926.701.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and Morrison Engineers, PLLC averages $1,820 (1 cited inspection).

Morrison Engineers, PLLC also files yearly injury logs with OSHA, summarized below.

Morrison Engineers, PLLC: OSHA citation items per year, 2010 to 2020
Citation items per year, by inspection date.

Want to know if OSHA cites Morrison Engineers, PLLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344627625 OPENED FEB 12, 2020Closed

Unprogrammed related · Partial · Safety · 31 employees at the site · Closed May 6, 2021

110 Kildaire Park Drive, Cary, NC 27518 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$2,800$1,820Jun 12, 2020Final

Inspection 313827495 OPENED JAN 12, 2010Closed

Complaint · Partial · Safety · 10 employees at the site · Closed Feb 4, 2010

700 E. Lawson/lincolin Street, Durham, NC 27707 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.152(d)(2) · Flammable liquids
Other-than-serious$0$0Jan 21, 2010Closed
Citation 1, item 2
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Other-than-serious$0$0Jan 21, 2010Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Cary site logged 0 recordable injuries or illnesses among about 27 workers: 0.0 per 100 full-time workers, against a median of 0.1 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Morrison Engineers Home Office
Cary · 2024
27 000.00.1
Morrison Engineers PLLC
Cary · 2022
28 000.00.6

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.152 · Flammable liquids

29 CFR 1926.152(d)(2)

(2) At least one portable fire extinguisher having a rating of not less than 20-B units shall be located not less than 25 feet, nor more than 75 feet, from any flammable liquid storage area located outside.

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.701(b)

(b) Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, shall be guarded to eliminate the hazard of impalement.

Other commercial and institutional building construction employers in North Carolina

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.