OSHA SearchOSHA records by employer

Morrison Products, Inc.: OSHA inspections and violations

Mesquite, Texas · Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing · NAICS 333413

2inspections
9citation items
$11,703current penalties
Jan 22, 2021last inspection

OSHA has inspected Morrison Products, Inc. 2 times in Texas since 1988.

The latest one began on Jan 22, 2021 on a referral, in Mesquite.

Those inspections ended with 9 citation items: 2 serious and 7 other-than-serious.

Penalties were first proposed at $23,406 and now stand at $11,703, 50% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 6 items under 1910.134.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Morrison Products, Inc. averages $11,703 (1 cited inspection).

Morrison Products, Inc. also files yearly injury logs with OSHA, summarized below.

It reported 2 severe injuries to OSHA since 2015.

Morrison Products, Inc.: OSHA citation items per year, 1988 to 2021
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

398employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Morrison Products, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345112726 OPENED JAN 22, 2021Closed

Referral · Complete · Safety · 130 employees at the site · Closed Aug 5, 2021

3400 Us Highway 80, Mesquite, TX 75149 · Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jan 21, 2021: Employee amputates finger in drill bit while using milling m

At 9:15 a.m. on January 21, 2021, an employee working as a machine operator for a manufacturer of air moving equipment (fans and blowers) was operating a milling machine in the tool room. While operating the machine, the employee caught his glove in a drill bit. The employee received medical treatment without hospitalization for an amputated finger.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$13,653$6,826Jul 9, 2021Final
Citation 1, item 2
29 CFR 1910.212(b) · Machine guarding
Serious$9,753$4,876Jul 9, 2021Final

Inspection 101432367 OPENED SEP 8, 1988Closed

Complaint · Partial · Health · 45 employees at the site · Closed Dec 16, 1988

3400 U. S. Highway 80, Mesquite, TX 75149 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(b)(1) · Respiratory protection
Other-than-serious$0$0Oct 14, 1988Closed
Citation 1, item 2
29 CFR 1910.134(b)(2) · Respiratory protection
Other-than-serious$0$0Oct 14, 1988Closed
Citation 1, item 3
29 CFR 1910.134(b)(3) · Respiratory protection
Other-than-serious$0$0Oct 14, 1988Closed
Citation 1, item 4
29 CFR 1910.134(b)(5) · Respiratory protection
Other-than-serious$0$0Oct 14, 1988Closed
Citation 1, item 5
29 CFR 1910.134(b)(6) · Respiratory protection
Other-than-serious$0$0Oct 14, 1988Closed
Citation 1, item 6
29 CFR 1910.134(b)(7) · Respiratory protection
Other-than-serious$0$0Oct 14, 1988Closed
Citation 1, item 7
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Oct 14, 1988Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Mesquite site logged 0 recordable injuries or illnesses among about 140 workers: 0.0 per 100 full-time workers, against a median of 2.4 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Morrison Products Dallas
Mesquite · 2025
140 000.02.4

Included with any plan: 9 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Aug 20, 2022, Mesquite: Hospitalization · fractures · leg(s), unspecified

An employee was climbing a fence in pursuit of two people who had been trying to break into a facility. He fell from the fence, suffered a broken left leg, and was hospitalized.

Jan 21, 2021, Mesquite: Amputation · amputations · finger(s), fingernail(s), n.e.c.

An employee was resurfacing a tool on a milling machine. The machine bit caught his right-hand glove and pulled in his ring finger. The finger was amputated at the second knuckle.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)

(h) Post-mortem data: Increased incidence and/or severity of post-mortem findings may be indicative of maternal toxicity. This can include gross or microscopic pathological findings or organ weight data, including absolute organ weight, organ-to-body weight ratio, or organ-to-brain weight ratio. When supported by findings of adverse histopathological effects in the affected organ(s), the observation of a significant change in the average weight of suspected target organ(s) of treated dams (mothers), compared to those in the control group, may be considered evidence of maternal toxicity.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(b)(1)

(1) Normal breathing. In a normal standing position, without talking, the subject shall breathe normally for 1 minute. After the normal breathing exercise, the subject needs to hold head straight ahead and hold his or her breath for 10 seconds during the test measurement.

29 CFR 1910.134(b)(2)

(2) Deep breathing. In a normal standing position, the subject shall breathe slowly and deeply for 1 minute, being careful not to hyperventilate. After the deep breathing exercise, the subject shall hold his or her head straight ahead and hold his or her breath for 10 seconds during test measurement.

29 CFR 1910.212 · Machine guarding

Other industrial and commercial fan and blower and air purification equipment manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.