OSHA SearchOSHA records by employer

Morton Buildings, Inc.: OSHA inspections and violations

Kenton, Ohio · Prefabricated Wood Building Manufacturing · NAICS 321992

11inspections
9citation items
$20,528current penalties
Jul 29, 2022last inspection

Since 1974, OSHA inspectors have visited Morton Buildings, Inc. in Ohio 11 times.

The most recent inspection opened on Jul 29, 2022 on a referral, in Jackson Center.

In all, OSHA issued 9 citation items: 6 serious and 3 other-than-serious.

The proposed penalties came to $42,506; today they stand at $20,528, 52% less.

The rule cited most here is 1926.502 (fall protection systems), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Morton Buildings, Inc. averages $13,653 across 1 cited inspection.

Morton Buildings, Inc. also files yearly injury logs with OSHA, summarized below.

It reported 2 severe injuries to OSHA since 2015.

Morton Buildings, Inc.: OSHA citation items per year, 1974 to 2022
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

263employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Morton Buildings, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Morton Buildings, Inc. at 14 sites in 2 states. Together they've had 28 inspections and $68,135 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 14 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 346110588 OPENED JUL 29, 2022Closed

Referral · Partial · Health · 15 employees at the site · Closed Feb 6, 2023

122 E. Pike Street, Jackson Center, OH 45334 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344911359 OPENED SEP 2, 2020Closed

Referral · Partial · Safety · 5 employees at the site · Closed Apr 14, 2021

26321 Hull Prairie Road, Perrysburg, OH 43551 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Incident on Aug 31, 2020: Employee falls from deck and incurs multiple injuries

At 3:15 p.m. on August 31, 2020, Employee #1, a 25-year-old male, was installing a deck at a residential barn. The employee was not using appropriate fall protection while working on the loft. While leaning on or stepping on an unsecured piece of plywood, the piece tipped, causing the employee to fall to the ground below. The fall resulted in multiple injuries, including a broken lower back, four broken ribs on the right side, a punctured lung cavity, a broken right shoulder blade, a fractured skull, a concussion, and middle back compression. The employee was hospitalized for treatment of the injuries.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.502(k)(4) · Fall protection systems
Serious$13,653$13,653Feb 10, 2021Final
Citation 1, item 2a
29 CFR 1926.502(d)(6)(i) · Fall protection systems
Serious$13,653$0Feb 10, 2021Final

Inspection 305117616 OPENED MAR 14, 2003Closed

Referral · Partial · Health · 60 employees at the site · Closed Aug 20, 2003

14483 St. Rt. 31, Kenton, OH 43326 · Prefabricated Wood Building Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Jun 5, 2003Closed

Inspection 305117590 OPENED MAR 11, 2003Closed

Complaint · Partial · Safety · 1,000 employees at the site · Closed Jan 21, 2004

14483 St. Rt. 31, Kenton, OH 43326 · Prefabricated Wood Building Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · General requirements
Serious$2,975$1,500Aug 12, 2003Closed
Citation 1, item 2
29 CFR 1910.136(a) · Foot protection
Other-than-serious$2,975$0Aug 12, 2003Closed
Citation 1, item 3
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$2,125$1,275Aug 12, 2003Closed
Citation 1, item 4
29 CFR 1910.213(k)(3) · Woodworking machinery
Serious$5,000$3,000Aug 12, 2003Closed
Citation 1, item 5
29 CFR 1910.242(b) · Hand and power tools
Serious$2,125$1,100Aug 12, 2003Closed

Inspection 301530374 OPENED AUG 27, 1997Closed

Planned · No inspection · Safety · Closed Aug 27, 1997

2051 Old Oak Harbor Rd., Fremont, OH 43420 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 301529913 OPENED AUG 19, 1997Closed

Planned · No inspection · Safety · Closed Aug 19, 1997

2051 Old Oak Harbor Rd., Fremont, OH 43420 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 106127129 OPENED APR 21, 1994Closed

Planned · No inspection · Safety · 3 employees at the site · Closed May 26, 1994

Waste Water Trtmnt. Plant, Sycamore, OH 44882 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 110290517 OPENED JAN 8, 1991Closed

Planned · No inspection · Safety · Closed Jan 8, 1991

2051 Old Oak Harbor Rd., Fremont, OH 43420 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

3 older inspections

Inspection 100095348 OPENED MAY 9, 1986Closed

Planned · Complete · Safety · 65 employees at the site · Closed Jul 24, 1986

Sr 31, South, Kenton, OH 43326 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Jul 3, 1986Closed

Inspection 214588196 OPENED APR 4, 1975Closed

Follow-up · Complete · Safety · 38 employees at the site · Closed Mar 10, 1984

State Route 31 South, Kenton, OH 43726 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 14534366 OPENED JUN 11, 1974Closed

Planned · Complete · Safety · 45 employees at the site · Closed Mar 10, 1984

State Route 31 South, Kenton, OH 43326 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2018, the Kenton site logged 1 recordable injury or illness among about 46 workers: 2.0 per 100 full-time workers, against a median of 3.9 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Morton Buildings #12
Kenton · 2018
46 102.03.9
Kenton #012
Kenton · 2017
48 000.00.6

Included with any plan: 1 more yearly log from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Jul 21, 2022, Jackson Center: Hospitalization · heat exhaustion, prostration · body systems

On July 21, 2022, an employee developed heat exhaustion while building roof trusses. After completing their shift, the employee was hospitalized.

Aug 31, 2020, Perrysburg: Hospitalization · soreness, pain, hurt-nonspecified injury · multiple body parts, n.e.c.

An employee was installing plywood/decking in a residential barn's attic. The employee fell to the ground about 14 feet below, suffering injuries to the back and arm, and was hospitalized.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.136 · Foot protection

29 CFR 1910.136(a)

(a) General requirements. The employer shall ensure that each affected employee uses protective footwear when working in areas where there is a danger of foot injuries due to falling or rolling objects, or objects piercing the sole, or when the use of protective footwear will protect the affected employee from an electrical hazard, such as a static-discharge or electric-shock hazard, that remains after the employer takes other necessary protective measures.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(h)(1)

(h) Radial saws. (1) The upper hood shall completely enclose the upper portion of the blade down to a point that will include the end of the saw arbor. The upper hood shall be constructed in such a manner and of such material that it will protect the operator from flying splinters, broken saw teeth, etc., and will deflect sawdust away from the operator. The sides of the lower exposed portion of the blade shall be guarded to the full diameter of the blade by a device that will automatically adjust itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection possible for the operation being performed.

29 CFR 1910.22 · General requirements

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1926.502 · Fall protection systems

Other prefabricated wood building manufacturing employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.