OSHA has inspected Morton Salt, Inc. 9 times in Ohio since 1975.

The latest one began on Aug 30, 2022 after a complaint, in Rittman.

Those inspections ended with 26 citation items: 3 serious and 23 other-than-serious.

Penalties were first proposed at $34,200 and now stand at $21,868, 36% lower after settlements or reviews.

Woodworking machinery comes up most often in these citations: 6 items under 1910.213.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,875, and Morton Salt, Inc. averages $7,126 (3 cited inspections).

Morton Salt, Inc. also files yearly injury logs with OSHA, summarized below.

It reported 2 severe injuries to OSHA since 2015.

Morton Salt, Inc.: OSHA citation items per year, 1975 to 2022
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

260employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Morton Salt, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Morton Salt, Inc. at 4 sites in 3 states. Together they've had 11 inspections and $31,354 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 4 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 346179971 OPENED AUG 30, 2022Closed

Complaint · Partial · Safety · 233 employees at the site · Closed Oct 18, 2022

151 South Industrial Ave, Rittman, OH 44270 · Spice and Extract Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.176(b) · Material storage and aisles
Other-than-serious$11,094$5,547Sep 30, 2022Final

Inspection 345113807 OPENED NOV 30, 2020Closed

Referral · Partial · Safety · 1,950 employees at the site · Closed Mar 9, 2021

151 South Industrial Ave, Rittman, OH 44270 · Spice and Extract Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Oct 20, 2020: Employee amputates fingertip while unclogging machine

At 3:45 a.m. on October 20, 2020, an employee was attempting to clear a jam in a free running bin. The employee removed a transition boot that was held in place with O-ring clamps and reached his hand in to remove clogged salt. When the salt became unclogged, the automated gate cycled, amputating his left index fingertip. He was taken to the hospital and released.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Other-than-serious$7,461$5,223Jan 27, 2021Final

Inspection 343722484 OPENED JAN 16, 2019Closed

Referral · Partial · Health · 237 employees at the site · Closed Mar 29, 2019

151 South Industrial Ave, Rittman, OH 44270 · Spice and Extract Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343659371 OPENED DEC 13, 2018Closed

Referral · Partial · Safety · 1,000 employees at the site · Closed Jun 7, 2019

151 South Industrial Ave, Rittman, OH 44270 · Spice and Extract Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Dec 7, 2018: Employee sustains second and third degree burns when splashe

At 5:00 p.m. on December 7, 2018, an employee was closing the ball valve when the valve broke off and sprayed him with 227 degrees of a hot liquid brine and salt solution. The employee sustained second and third degree burns to his right arm, arm pit, and abdomen. The employee was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.29(b)(3) · Fall protection systems in general industry
Serious$9,472$6,630Apr 8, 2019Final
Citation 1, item 2a
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Serious$5,683$3,978Apr 8, 2019Final
Citation 1, item 2b
29 CFR 1910.138(a) · Gloves and hand protection
Serious$0$0Apr 8, 2019Final

Inspection 339510513 OPENED DEC 5, 2013Closed

Complaint · Partial · Safety · 4,000 employees at the site · Closed Jan 21, 2014

151 Industrial Street, Rittman, OH 44270 · All Other Miscellaneous Chemical Product and Preparation Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313455362 OPENED AUG 5, 2009Closed

Unprogrammed related · Partial · Health · 266 employees at the site · Closed Aug 31, 2009

151 S. Industrial Street, Rittman, OH 44270 · All Other Miscellaneous Chemical Product and Preparation Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 16030926 OPENED OCT 20, 1976Closed

Follow-up · Complete · Health · 343 employees at the site · Closed Mar 10, 1984

151 S Industrial Ave, Rittman, OH 44270 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 15978802 OPENED NOV 25, 1975Closed

Complaint · Complete · Safety · 311 employees at the site · Closed Feb 2, 1977

151 South Industrial Street, Rittman, OH 44270 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(i)(2) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Jan 30, 1976Closed
Citation 1, item 2
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Jan 30, 1976Closed
Citation 1, item 3
29 CFR 1910.252(e)(2)(iii) · Welding fire safety
Other-than-serious$30$30Jan 30, 1976Closed
Citation 1, item 4 Other-than-serious$0$0Jan 30, 1976Closed
Citation 1, item 5
29 CFR 1910.213(h)(4) · Woodworking machinery
Other-than-serious$0$0Jan 30, 1976Closed
Citation 1, item 6
29 CFR 1910.213(h)(1) · Woodworking machinery
Other-than-serious$30$30Jan 30, 1976Closed
Citation 1, item 7
29 CFR 1910.213(h)(2) · Woodworking machinery
Other-than-serious$30$30Jan 30, 1976Closed
Citation 1, item 8
29 CFR 1910.213(h)(5) · Woodworking machinery
Other-than-serious$0$0Jan 30, 1976Closed
Citation 1, item 9
29 CFR 1910.213(b)(3) · Woodworking machinery
Other-than-serious$0$0Jan 30, 1976Closed
Citation 1, item 10
29 CFR 1910.213(c)(2) · Woodworking machinery
Other-than-serious$0$0Jan 30, 1976Closed
Citation 1, item 11
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Jan 30, 1976Closed
Citation 1, item 12
29 CFR 1910.244(b) · Other portable tools and equipment
Other-than-serious$45$45Jan 30, 1976Closed
Citation 1, item 13
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Other-than-serious$45$45Jan 30, 1976Closed
Citation 1, item 14
29 CFR 1910.106(e)(2)(ii) · Flammable liquids
Other-than-serious$45$45Jan 30, 1976Closed
Citation 1, item 15
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Other-than-serious$45$45Jan 30, 1976Closed
Citation 1, item 16
29 CFR 1910.106(e)(7)(ib) · Flammable liquids
Other-than-serious$65$65Jan 30, 1976Closed
Citation 1, item 17
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Other-than-serious$50$50Jan 30, 1976Closed
Citation 1, item 18
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Other-than-serious$30$30Jan 30, 1976Closed
Citation 1, item 19 Other-than-serious$45$45Jan 30, 1976Closed
Citation 1, item 20 Other-than-serious$0$0Jan 30, 1976Closed
Citation 1, item 21
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$30$30Jan 30, 1976Closed
1 older inspection

Inspection 214933616 OPENED APR 24, 1975Closed

Planned · Complete · Safety · 41 employees at the site · Closed Mar 10, 1984

667 Seville Road, Wadsworth, OH 44281 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Rittman site logged 9 recordable injuries or illnesses among about 222 workers: 3.9 per 100 full-time workers, against a median of 3.0 for its industry. Those cases cost 23 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Morton Salt
Rittman · 2025
222 923.93.0
Morton Salt Rittman
Rittman · 2021
228 100.43.0
Morton Salt, Inc
Rittman · 2019
243 1646.53.0
Morton Salt- Rittman, OH
Rittman · 2016
225 210.93.0

Included with any plan: 3 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Oct 20, 2020, Rittman: Amputation · amputations · fingertip(s)

An employee was clearing a blockage on a piece of equipment when the slide gate closed on his hand and amputated the left index fingertip.

Dec 7, 2018, Rittman: Hospitalization · third or fourth degree heat (thermal) burns · forearm(s)

An employee was performing a routine check of the retainer system. He opened a valve to flush the solution back through the closed-loop system into the tank when a part of the valve failed. The heated solution struck the employee causing second degree burns to the right side of the torso and third degree burns to the right forearm.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(2)(i)

(2) Design, construction, and capacity of containers—(i) General. Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable.

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.138 · Gloves and hand protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.176 · Material storage and aisles

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.244 · Other portable tools and equipment

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.29 · Fall protection systems in general industry

29 CFR 1910.309

29 CFR 1910.94 · Ventilation

Other spice and extract manufacturing employers in Ohio