OSHA SearchOSHA records by employer

Mosaico Business & Community Development Corp.: OSHA inspections and violations

Bristol, Rhode Island · Commercial and Institutional Building Construction · NAICS 236220

1inspections
4citation items
$2,200current penalties
Feb 3, 2016last inspection

OSHA has inspected Mosaico Business & Community Development Corp. once in Rhode Island.

The inspection began on Feb 3, 2016 on a referral, in Bristol.

That inspection ended with 4 citation items: 3 serious and 1 other-than-serious.

Penalties were first proposed at $4,800 and now stand at $2,200, 54% lower after settlements or reviews.

Woodworking machinery comes up most often in these citations: 3 items under 1910.213.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Mosaico Business & Community Development Corp. averages $2,200 (1 cited inspection).

Mosaico Business & Community Development Corp.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Rhode Island · latest 90 days of OSHA records

79employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Rhode Island: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Rhode Island

Checking a subcontractor, a client or your own company? Watch Mosaico Business & Community Development Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341221877 OPENED FEB 3, 2016Closed

Referral · Partial · Safety · 8 employees at the site · Closed Jan 31, 2017

# 315 500 Wood St., Bristol, RI 02809 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$2,800$2,200Mar 28, 2016Final
Citation 1, item 1b
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$0$0Mar 28, 2016Final
Citation 1, item 1c
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Mar 28, 2016Final
Citation 1, item 2
29 CFR 1910.305(b)(3)(ii) · Electrical wiring methods
Other-than-serious$2,000$0Mar 28, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(c)(1)

(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1910.213(c)(2)

(2) Each hand-fed circular ripsaw shall be furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator. The spreader shall be made of hard tempered steel, or its equivalent, and shall be thinner than the saw kerf. It shall be of sufficient width to provide adequate stiffness or rigidity to resist any reasonable side thrust or blow tending to bend or throw it out of position. The spreader shall be attached so that it will remain in true alignment with the saw even when either the saw or table is tilted. The provision of a spreader in connection with grooving, dadoing, or rabbeting is not required. On the completion of such operations, the spreader shall be immediately replaced.

29 CFR 1910.213(c)(3)

(3) Each hand-fed circular ripsaw shall be provided with nonkickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator. They shall be designed to provide adequate holding power for all the thicknesses of materials being cut.

29 CFR 1910.305 · Electrical wiring methods

Other commercial and institutional building construction employers in Rhode Island

Alert subscribers get notified of each newly cited employer in Rhode Island the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.