OSHA SearchOSHA records by employer

Mosarr Services LLC: OSHA inspections and violations

Colorado Springs, Colorado · Other Foundation, Structure, and Building Exterior Contractors · NAICS 238190

1inspections
4citation items
$3,000current penalties
Apr 3, 2025last inspection

OSHA inspectors have visited Mosarr Services LLC in Colorado one time.

It opened on Apr 3, 2025 after a complaint, in Colorado Springs and is still open.

In all, OSHA issued 4 citation items: 3 serious and 1 other-than-serious.

The proposed penalties came to $10,639; today they stand at $3,000, 72% less.

The rule cited most here is 1926.651 (excavations), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Mosarr Services LLC averages $3,000 across 1 cited inspection.

Mosarr Services LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Mosarr Services LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348158155 OPENED APR 3, 2025Open

Complaint · Partial · Safety · 4 employees at the site · Open

1612 Grand Overlook Street, Colorado Springs, CO 80910 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(l) · Excavations
Serious$2,837$1,500Jul 14, 2025Final
Citation 1, item 2a
29 CFR 1926.652(a)(1) · Trench protection
Serious$4,965$1,500Jul 14, 2025Final
Citation 1, item 2b
29 CFR 1926.651(k)(1) · Excavations
Serious$0$0Jul 14, 2025Final
Citation 1, item 3
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Other-than-serious$2,837$0Jul 14, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.651(l)

(l) Walkways shall be provided where employees or equipment are required or permitted to cross over excavations. Guardrails which comply with § 1926.502(b) shall be provided where walkways are 6 feet (1.8 m) or more above lower levels.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(a)(1)

(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other other foundation, structure, and building exterior contractors employers in Colorado

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.