OSHA SearchOSHA records by employer

Moses Electric, Inc.: OSHA inspections and violations

Jackson, Mississippi · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

11inspections
7citation items
$2,675current penalties
Oct 10, 2024last inspection

OSHA has inspected Moses Electric, Inc. 11 times in Mississippi since 1984.

The latest one began on Oct 10, 2024 after a complaint, in Mississippi State.

Those inspections ended with 7 citation items: 4 serious and 3 other-than-serious.

Penalties were first proposed at $10,338 and now stand at $2,675, 74% lower after settlements or reviews.

Ground-fault protection on job sites comes up most often in these citations: 3 items under 1926.404.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Moses Electric, Inc. averages $0 (1 cited inspection).

It reported 2 severe injuries to OSHA since 2015.

Moses Electric, Inc.: OSHA citation items per year, 1984 to 2024
Citation items per year, by inspection date.

Mississippi · latest 90 days of OSHA records

16employers cited

Get notified the morning OSHA posts each new citation in Mississippi: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Mississippi

Checking a subcontractor, a client or your own company? Watch Moses Electric, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347812257 OPENED OCT 10, 2024Closed

Complaint · Partial · Safety · 16 employees at the site · Closed Dec 13, 2024

710 Bully Boulevard, Mississippi State, MS 39762 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.51(c)(1) · Sanitation
Other-than-serious$4,113$0Nov 26, 2024Final

Inspection 346382823 OPENED DEC 8, 2022Closed

Planned · Complete · Safety · 2 employees at the site · Closed Mar 30, 2023

755 Simpson Highway, Pinola, MS 39149 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344150545 OPENED JUL 10, 2019Closed

Planned · Complete · Safety · 2 employees at the site · Closed Jul 12, 2019

213 Brooks St, Pelahatchie, MS 39145 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342894763 OPENED JAN 23, 2018Closed

Referral · Partial · Safety · 148 employees at the site · Closed Mar 28, 2018

705 Peyton St 466 W Bridge St, Yazoo City, MS 39194 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jan 22, 2018: Employee working close to power line is shocked and burned

At 8:00 a.m. on January 22, 2018, Employee #1, employed by an electrical services company, was working from an aerial lift and changing light pole fixtures. He moved too close to a live power line and sustained an electrical shock. Emergency services were called, and Employee #1 was transported to the hospital, admitted, and treated for third degree electrical burns.

No citations from this inspection.

Inspection 340882208 OPENED AUG 26, 2015Closed

Planned · Partial · Safety · 2 employees at the site · Closed Oct 13, 2015

6540 Watkins Blvd, Jackson, MS 39213 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 308774850 OPENED MAR 28, 2007Closed

Unprogrammed other · Partial · Safety · 40 employees at the site · Closed May 29, 2007

2500 North State Street, Jackson, MS 39211 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(h) · Electrical equipment on job sites
Other-than-serious$700$0May 21, 2007Closed
Citation 1, item 2
29 CFR 1926.405(e)(1) · Job-site wiring
Other-than-serious$875$0May 21, 2007Closed

Inspection 304313430 OPENED MAR 22, 2002Closed

Planned · Partial · Safety · 3 employees at the site · Closed Apr 30, 2002

1021 Popps Ferry Road, Biloxi, MS 39530 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(h) · Electrical equipment on job sites
Serious$1,250$600Apr 1, 2002Closed
Citation 1, item 2
29 CFR 1926.404(e)(1)(iv) · Ground-fault protection on job sites
Serious$2,500$1,500Apr 1, 2002Closed

Inspection 301035887 OPENED JUN 18, 1998Closed

Unprogrammed related · Complete · Safety · 8 employees at the site · Closed Jul 23, 1998

Mvsu, Administration Building, Itta Bena, MS 38941 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(a)(2) · Ground-fault protection on job sites
Serious$675$350Jun 26, 1998Closed
3 older inspections

Inspection 109255588 OPENED JUN 16, 1995Closed

Unprogrammed related · Complete · Safety · 3 employees at the site · Closed Jul 24, 1995

U. S. Highway 80, Brandon, MS 39042 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$225$225Jun 27, 1995Closed

Inspection 18281998 OPENED AUG 25, 1988Closed

Planned · Complete · Safety · 8 employees at the site · Closed Aug 30, 1988

400 E. Capital Street, Jackson, MS 39201 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 1680651 OPENED APR 4, 1984Closed

Planned · Complete · Safety · 5 employees at the site · Closed Mar 16, 2016

Best Western Motel Cornor Hwy 80 & Ellis Ave, Jackson, MS 39209 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Jan 22, 2018, Yazoo City: Hospitalization · third or fourth degree electrical burns · nonclassifiable

An employee was in a lift changing light fixtures on a pole in front of a house when he contacted a powerline and was shocked, suffering third degree burns.

Feb 12, 2016, Itta Bena: Hospitalization, amputation · amputations · toes(s), toenail(s)

An employee was operating an auger to drill holes for electrical poles when an auger fell on the employee's right foot, amputating a toe.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(h)

(h) Identification of disconnecting means and circuits. Each disconnecting means required by this subpart for motors and appliances shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. These markings shall be of sufficient durability to withstand the environment involved.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(a)(2)

(2) Polarity of connections. No grounded conductor shall be attached to any terminal or lead so as to reverse designated polarity.

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.51 · Sanitation

Other electrical contractors and other wiring installation contractors employers in Mississippi

Alert subscribers get notified of each newly cited employer in Mississippi the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.