OSHA SearchOSHA records by employer

Motus Excavation, LLC: OSHA inspections and violations

Provo, Utah · Water and Sewer Line and Related Structures Construction · NAICS 237110

1inspections
6citation items
$2,625current penalties
Sep 27, 2021last inspection

OSHA has inspected Motus Excavation, LLC once in Utah.

The inspection began on Sep 27, 2021 after an accident, in Provo.

That inspection ended with 6 citation items: 5 serious and 1 other-than-serious.

Penalties were first proposed at $5,250 and now stand at $2,625, 50% lower after settlements or reviews.

Excavations comes up most often in these citations: 3 items under 1926.651.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Motus Excavation, LLC averages $2,625 (1 cited inspection).

Motus Excavation, LLC: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

67employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Motus Excavation, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345550032 OPENED SEP 27, 2021Closed

Accident · Partial · Safety · 35 employees at the site · Closed Nov 16, 2021

928 W. 1560 S., Provo, UT 84601 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR UCA 34A-6-201(1)(A)
Serious$2,500$1,250Oct 25, 2021Final
Citation 1, item 2a
29 CFR 1926.651(c)(2) · Excavations
Serious$2,500$1,250Oct 25, 2021Final
Citation 1, item 2b
29 CFR 1926.651(j)(2) · Excavations
Serious$0$0Oct 25, 2021Final
Citation 1, item 2c
29 CFR 1926.651(k)(1) · Excavations
Serious$0$0Oct 25, 2021Final
Citation 1, item 2d
29 CFR 1926.652(a)(1) · Trench protection
Serious$0$0Oct 25, 2021Final
Citation 2, item 1
29 CFR UAC R614-1-5.B.2
Other-than-serious$250$125Oct 25, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

Other water and sewer line and related structures construction employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.