OSHA SearchOSHA records by employer

Mount Arlington DPW: OSHA inspections and violations

Mount Arlington, New Jersey · Facilities Support Services · NAICS 561210

2inspections
4citation items
$11,200current penalties
Aug 14, 2015last inspection

Mount Arlington DPW has 2 OSHA inspections on record in New Jersey, the first in 2015.

OSHA's last visit started on Aug 14, 2015 to follow up on an earlier case, in Mount Arlington.

Across those inspections OSHA issued 4 citation items: 4 serious.

OSHA proposed $11,200 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.305, electrical wiring methods (2 items).

For context, across all staffing, cleaning and waste services employers the median penalty per cited inspection since 2015 is $2,208. Mount Arlington DPW averages $11,200 over 1 cited inspection in that time.

Mount Arlington DPW: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

269employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Mount Arlington DPW and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340847730 OPENED AUG 14, 2015Closed

Follow-up · Partial · Safety · Local government · 6 employees at the site · Closed Aug 14, 2015

1 Aldenbrand Ave, Mount Arlington, NJ 07856 · Facilities Support Services · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340744937 OPENED JUN 30, 2015Closed

Planned · Complete · Safety · Local government · 6 employees at the site · Closed Aug 14, 2015

1 Altenbrand Ave, Mount Arlington, NJ 07856 · Facilities Support Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Serious$2,800$2,800Jul 8, 2015Final
Citation 1, item 2
29 CFR 1910.304(b)(4) · Grounding and circuit protection
Serious$2,800$2,800Jul 8, 2015Final
Citation 1, item 3
29 CFR 1910.305(a)(2) · Electrical wiring methods
Serious$2,800$2,800Jul 8, 2015Final
Citation 1, item 4
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$2,800$2,800Jul 8, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(7)(i)

(i) Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment.

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.304(b)(4)

(4) Outlet devices. Outlet devices shall have an ampere rating not less than the load to be served and shall comply with the following provisions:

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(a)(2)

(2) Temporary wiring. Except as specifically modified in this paragraph, all other requirements of this subpart for permanent wiring shall also apply to temporary wiring installations.

Other facilities support services employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.