OSHA SearchOSHA records by employer

Mountain High Custom Concrete, LLC: OSHA inspections and violations

Gypsum, Colorado · Poured Concrete Foundation and Structure Contractors · NAICS 238110

2inspections
2citation items
$3,722current penalties
Sep 4, 2019last inspection

Mountain High Custom Concrete, LLC has 2 OSHA inspections on record in Colorado, the first in 2019.

OSHA's last visit started on Sep 4, 2019 to follow up on an earlier case, in Gypsum.

Across those inspections OSHA issued 2 citation items: 2 serious.

OSHA proposed $3,722 in penalties and the amount has not been reduced.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Mountain High Custom Concrete, LLC averages $3,722 over 1 cited inspection in that time.

Mountain High Custom Concrete, LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

138employers cited

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Mountain High Custom Concrete, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344284724 OPENED SEP 4, 2019Closed

Follow-up · No inspection · Safety · Closed Sep 4, 2019

461 Railroad Avenue, Gypsum, CO 81637 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343991162 OPENED MAY 7, 2019Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Nov 12, 2019

461 Railroad Ave, Gypsum, CO 81637 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(a)(1) · Trench protection
Serious$2,273$2,273Jun 27, 2019Final
Citation 1, item 2
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$1,449$1,449Jun 27, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(a)(1)

(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.701(b)

(b) Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, shall be guarded to eliminate the hazard of impalement.

Other poured concrete foundation and structure contractors employers in Colorado