Inspection 343700217 OPENED JAN 8, 2019Closed
J- Line Flaggin Quarters Foley Square, New York, NY 10013 · Mixed Mode Transit Systems · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2018, OSHA inspectors have visited Mta NYCT Chambers Street Station in New York 2 times.
The most recent inspection opened on Jan 8, 2019 to follow up on an earlier case, in New York.
In all, OSHA issued 7 citation items: 7 serious.
No penalty came with these citations.
The rule cited most here is 1910.305 (electrical wiring methods), 5 times.
Among transportation and warehousing employers, the typical cited inspection since 2015 ends with a $2,420 penalty. Mta NYCT Chambers Street Station averages $0 across 1 cited inspection.
New York · latest 90 days of OSHA records
360employers cited
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Mta NYCT Chambers Street Station and get notified the morning OSHA posts a new citation for it.
Watch this companyJ- Line Flaggin Quarters Foley Square, New York, NY 10013 · Mixed Mode Transit Systems · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
111 Worth Street, New York, NY 10013 · Mixed Mode Transit Systems · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.37(a)(3) · Exit routes |
Serious | $0 | $0 | Sep 26, 2018 | Final |
| Citation 1, item 2 29 CFR 1910.37(a)(4) · Exit routes |
Serious | $0 | $0 | Sep 26, 2018 | Final |
| Citation 1, item 3 29 CFR 1910.305(a)(2)(ii) · Electrical wiring methods |
Serious | $0 | $0 | Sep 26, 2018 | Final |
| Citation 1, item 4 29 CFR 1910.305(a)(2)(ix) · Electrical wiring methods |
Serious | $0 | $0 | Sep 26, 2018 | Final |
| Citation 1, item 5 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Serious | $0 | $0 | Sep 26, 2018 | Final |
| Citation 1, item 6 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Serious | $0 | $0 | Sep 26, 2018 | Final |
| Citation 1, item 7 29 CFR 1910.305(j)(1)(i) · Electrical wiring methods |
Serious | $0 | $0 | Sep 26, 2018 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.305(a)(2)(ii)
(ii) Temporary wiring shall be removed immediately upon completion of the project or purpose for which the wiring was installed.
29 CFR 1910.305(a)(2)(ix)
(ix) All lamps for general illumination shall be protected from accidental contact or breakage by a suitable fixture or lampholder with a guard. Brass shell, paper-lined sockets, or other metal-cased sockets may not be used unless the shell is grounded.
29 CFR 1910.305(b)(1)(ii)
(ii) Unused openings in cabinets, boxes, and fittings shall be effectively closed.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.