OSHA SearchOSHA records by employer

Mueller Water Products, Inc.: OSHA inspections and violations

Cleveland, North Carolina · Totalizing Fluid Meter and Counting Device Manufacturing · NAICS 334514

2inspections
3citation items
$5,925current penalties
Jun 10, 2019last inspection

Mueller Water Products, Inc. has 2 OSHA inspections on record in North Carolina, the first in 2019.

OSHA's last visit started on Jun 10, 2019 after a complaint, in Cleveland.

Across those inspections OSHA issued 3 citation items: 1 serious and 2 other-than-serious.

OSHA proposed $7,500 in penalties. After settlements and reviews the total is $5,925, down 21%.

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Mueller Water Products, Inc. averages $5,925 over 1 cited inspection in that time.

Mueller Water Products, Inc. also files yearly injury logs with OSHA, summarized below.

Mueller Water Products, Inc.: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

234employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Mueller Water Products, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Mueller Water Products, Inc. at 3 sites in 2 states. Together they've had 7 inspections and $41,165 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 3 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 344069125 OPENED JUN 10, 2019Closed

Complaint · Partial · Health · 172 employees at the site · Closed Sep 6, 2022

10210 Statesville Boulevard, Cleveland, NC 27013 · Totalizing Fluid Meter and Counting Device Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$6,300$4,725Aug 2, 2019Final
Citation 2, item 1
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0Aug 2, 2019Final
Citation 2, item 2
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$1,200$1,200Aug 2, 2019Final

Inspection 344017694 OPENED MAY 17, 2019Closed

Complaint · Partial · Safety · 200 employees at the site · Closed May 23, 2019

10210 Statesville Blvd., Cleveland, NC 27013 · Totalizing Fluid Meter and Counting Device Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Cleveland site logged 1 recordable injury or illness among about 106 workers: 1.0 per 100 full-time workers, against a median of 0.3 for its industry. Those cases cost 180 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Mueller Systems
Cleveland · 2024
106 111.00.3

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(g)(8)

(8) The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s). (Electronic access and other alternatives to maintaining paper copies of the safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.)

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.242(b)

(b) Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment.

Other totalizing fluid meter and counting device manufacturing employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.