Inspection 347491292 OPENED MAY 20, 2024Closed
950 Breezewood Lane, Neenah, WI 54956 · Commercial Printing (except Screen and Books) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2022, OSHA inspectors have visited Multi-Color Corporation in Wisconsin 4 times.
The most recent inspection opened on May 20, 2024 after a complaint, in Neenah.
In all, OSHA issued 12 citation items: 9 serious and 3 other-than-serious.
The proposed penalties came to $59,503; today they stand at $22,939, 61% less.
The rule cited most here is 1910.147 (lockout/tagout), 5 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Multi-Color Corporation averages $11,470 across 2 cited inspections.
Multi-Color Corporation also files yearly injury logs with OSHA, summarized below.
Wisconsin · latest 90 days of OSHA records
229employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Wisconsin
Checking a subcontractor, a client or your own company? Watch Multi-Color Corporation and get notified the morning OSHA posts a new citation for it.
Watch this companyOSHA records show Multi-Color Corporation at 9 sites in 6 states. Together they've had 22 inspections and $78,518 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 9 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
See plans950 Breezewood Lane, Neenah, WI 54956 · Commercial Printing (except Screen and Books) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
950 Breezewood Lane, Neenah, WI 54956 · Commercial Printing (except Screen and Books) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.106(d)(4)(i) · Flammable liquids |
Other-than-serious | $12,278 | $0 | Feb 8, 2023 | Final |
| Citation 1, item 2a 29 CFR 1910.147(c)(4)(ii) · Lockout/tagout |
Serious | $15,625 | $12,278 | Feb 8, 2023 | Final |
| Citation 1, item 2b 29 CFR 1910.147(c)(7)(i) · Lockout/tagout |
Serious | $0 | $0 | Feb 8, 2023 | Final |
| Citation 1, item 2c 29 CFR 1910.147(d) · Lockout/tagout |
Serious | $0 | $0 | Feb 8, 2023 | Final |
| Citation 1, item 2d 29 CFR 1910.147(f)(3)(i) · Lockout/tagout |
Serious | $12,278 | $0 | Feb 8, 2023 | Final |
| Citation 1, item 2e 29 CFR 1910.147(f)(3)(ii)(d) · Lockout/tagout |
Serious | $0 | $0 | Feb 8, 2023 | Final |
| Citation 1, item 4a 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $12,278 | $6,139 | Feb 8, 2023 | Final |
| Citation 1, item 4b 29 CFR 1910.212(a)(2) · Machine guarding |
Serious | $0 | $0 | Feb 8, 2023 | Final |
1102 Jefferson Street, Algoma, WI 54201 · Commercial Printing (except Screen and Books) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1102 Jefferson Street, Algoma, WI 54201 · Paint and Coating Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1b 29 CFR 1910.37(a)(3) · Exit routes |
Other-than-serious | $0 | $1,000 | Sep 30, 2022 | Final |
| Citation 1, item 2a 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Other-than-serious | $7,044 | $0 | Sep 30, 2022 | Final |
| Citation 1, item 2b 29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods |
Serious | $0 | $3,522 | Sep 30, 2022 | Final |
| Citation 1, item 2c 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $0 | $0 | Sep 30, 2022 | Final |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the Neenah site logged 3 recordable injuries or illnesses among about 125 workers: 3.0 per 100 full-time workers, against a median of 2.0 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Multi Color Corporation Neenah · 2024 | 125 | 3 | 0 | 3.0 | 2.0 |
| Multi-Color Corporation Neenah · 2022 | 157 | 6 | 2 | 4.5 | 2.0 |
| Multi-Color Corporation - Neenah Neenah · 2021 | 149 | 13 | 1 | 9.7 | 2.0 |
| Algoma site Algoma · 2020 | 350 | 8 | 0 | 2.2 | 2.0 |
Included with any plan: 2 more yearly logs from these sites, back to 2019, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(d)(4)(i)
(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra
29 CFR 1910.147(c)(4)(ii)
(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:
29 CFR 1910.147(c)(7)(i)
(7) Training and communication. (i) The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:
Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.