OSHA SearchOSHA records by employer

Multicircuits Inc.: OSHA inspections and violations

Oshkosh, Wisconsin · Bare Printed Circuit Board Manufacturing · NAICS 334412

1inspections
4citation items
$9,282current penalties
Mar 12, 2019last inspection

OSHA inspectors have visited Multicircuits Inc. in Wisconsin one time.

It opened on Mar 12, 2019 on a referral, in Oshkosh.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $18,564; today they stand at $9,282, 50% less.

The rule cited most here is 1910.147 (lockout/tagout), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Multicircuits Inc. averages $9,282 across 1 cited inspection.

Multicircuits Inc. also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

Multicircuits Inc.: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites Multicircuits Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343843108 OPENED MAR 12, 2019Closed

Referral · Partial · Safety · 71 employees at the site · Closed Sep 30, 2019

2301 Universal Street, Oshkosh, WI 54904 · Bare Printed Circuit Board Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Mar 5, 2019: Employee suffers skull fracture and ear amputation when crus

At 9:00 p.m. on March 5, 2019, an employee was changing the water on a bath rinse tank on a Baker Technology/Hi-Ji Automated Electrolytic Plating line. He was standing between the carriage and frame of the machine and had not locked out the bath rinse tank. The carriage began moving and the employee was unable to get out of the way, resulting in his head becoming crushed between the carriage and frame of the machine. The employee was hospitalized and suffered a skull fracture and a partial ear amputation.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$9,282$9,282Aug 30, 2019Final
Citation 1, item 1b
29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout
Serious$0$0Aug 30, 2019Final
Citation 1, item 1c
29 CFR 1910.147(d) · Lockout/tagout
Serious$0$0Aug 30, 2019Final
Citation 1, item 1d
29 CFR 1910.212(a)(1) · Machine guarding
Serious$9,282$0Aug 30, 2019Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Oshkosh site logged 1 recordable injury or illness among about 76 workers: 1.3 per 100 full-time workers, against a median of 0.5 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Multicircuits Inc
Oshkosh · 2025
76 101.30.5

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Mar 5, 2019, Oshkosh: Hospitalization · fractures and other injuries, n.e.c. · multiple head locations

An employee was standing between the carriage and the machine frame to change a water rinse bath on an auto plating line. The carriage began moving and the employee's head was crushed between the carriage and the plating line frame, causing a skull fracture and a partial ear avulsion.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(7)(i)(a)

(A) Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.

29 CFR 1910.147(d)

(d) Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:

29 CFR 1910.212 · Machine guarding

Other bare printed circuit board manufacturing employers in Wisconsin

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.