Naro Construction LLC: OSHA inspections and violations

Monroe Township, New Jersey · Masonry Contractors · NAICS 238140

1inspections
6citation items
$2,800current penalties
Apr 8, 2016last inspection

Naro Construction LLC has one OSHA inspection on record in New Jersey.

OSHA opened it on Apr 8, 2016 as a planned inspection, in Monroe Township.

From that inspection OSHA issued 6 citation items: 6 serious.

OSHA proposed $2,800 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Naro Construction LLC averages $2,800 over 1 cited inspection in that time.

Naro Construction LLC: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

269employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Naro Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341387306 OPENED APR 8, 2016Closed

Planned · Partial · Safety · 4 employees at the site · Closed Dec 5, 2019

15 Brentwood Place, Monroe Township, NJ 08831 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$2,800$2,800May 27, 2016Final
Citation 1, item 1b
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$0$0May 27, 2016Final
Citation 1, item 1c
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$0$0May 27, 2016Final
Citation 1, item 1d
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0May 27, 2016Final
Citation 1, item 1e
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0May 27, 2016Final
Citation 1, item 1f
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$0$0May 27, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(1)

(c) Criteria for supported scaffolds. (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.452 · Rules for each type of scaffold