OSHA SearchOSHA records by employer

National Building Contractors, Inc.: OSHA inspections and violations

Decatur, Georgia · Roofing Contractors · NAICS 238160

4inspections
5citation items
$17,002current penalties
Feb 8, 2023last inspection

OSHA has inspected National Building Contractors, Inc. 4 times in Georgia since 2005.

The latest one began on Feb 8, 2023 as a planned inspection, in Gainesville.

Those inspections ended with 5 citation items: 4 serious and 1 other-than-serious.

Penalties were first proposed at $11,752 and still stand at $17,002.

Aerial lifts comes up most often in these citations: 2 items under 1926.453.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and National Building Contractors, Inc. averages $14,502 (1 cited inspection).

It reported 1 severe injury to OSHA since 2015.

National Building Contractors, Inc.: OSHA citation items per year, 2005 to 2023
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

150employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch National Building Contractors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346492176 OPENED FEB 8, 2023Closed

Planned · Complete · Safety · 30 employees at the site · Closed Feb 14, 2023

2875 Browns Bridge Road, Gainesville, GA 30504 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345866024 OPENED MAR 30, 2022Closed

Referral · Partial · Safety · 1 employee at the site · Closed Sep 8, 2022

998 Cole Drive Sw, Lilburn, GA 30047 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(a)(3) · Electrical safety in construction
Other-than-serious$7,252$14,502Aug 12, 2022Final

Inspection 309622009 OPENED DEC 18, 2006Closed

Planned · Complete · Safety · 26 employees at the site · Closed Mar 30, 2007

4800 Braircliff Road, Tucker, GA 30084 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.502(h)(1)(v) · Fall protection systems
Serious$1,500$1,000Mar 9, 2007Closed

Inspection 307840918 OPENED AUG 31, 2005Closed

Planned · Complete · Safety · 25 employees at the site · Closed Feb 22, 2006

487 Winn Way, Decatur, GA 30030 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$1,500$750Sep 9, 2005Closed
Citation 1, item 1b
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$0$0Sep 9, 2005Closed
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$750Sep 9, 2005Closed

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Mar 27, 2022, Lilburn: Hospitalization · electrical burns, unspecified · nonclassifiable

An employee was working from an aerial lift, about 20 feet in the air, when he contacted an electrical wire and suffered severe burns.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(3)

(3) Before work is begun the employer shall ascertain by inquiry or direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, is so located that the performance of the work may bring any person, tool, or machine into physical or electrical contact with the electric power circuit. The employer shall post and maintain proper warning signs where such a circuit exists. The employer shall advise employees of the location of such lines, the hazards involved, and the protective measures to be taken.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.453(b)(2)(iv)

(iv) Employees shall always stand firmly on the floor of the basket, and shall not sit or climb on the edge of the basket or use planks, ladders, or other devices for a work position.

29 CFR 1926.453(b)(2)(v)

(v) A body belt shall be worn and a lanyard attached to the boom or basket when working from an aerial lift.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

Other roofing contractors employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.