OSHA SearchOSHA records by employer

National Chimney Kentucky LLC: OSHA inspections and violations

Mount Sterling, Kentucky · Fabricated Pipe and Pipe Fitting Manufacturing · NAICS 332996

1inspections
3citation items
$9,600current penalties
Jan 25, 2022last inspection

OSHA inspectors have visited National Chimney Kentucky LLC in Kentucky one time.

It opened on Jan 25, 2022 after a complaint, in Mount Sterling.

In all, OSHA issued 3 citation items: 3 serious.

The penalties, $9,600 in total, stand where OSHA first set them.

The rule cited most here is 1910.255 (resistance welding), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. National Chimney Kentucky LLC averages $9,600 across 1 cited inspection.

National Chimney Kentucky LLC: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Kentucky · latest 90 days of OSHA records

191employers cited

Get notified the morning OSHA posts each new citation in Kentucky: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Kentucky

Checking a subcontractor, a client or your own company? Watch National Chimney Kentucky LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345743330 OPENED JAN 25, 2022Closed

Complaint · Partial · Safety · 7 employees at the site · Closed Oct 4, 2022

211 Windsor Drive, Mount Sterling, KY 40353 · Fabricated Pipe and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$3,200$3,200Jul 18, 2022Final
Citation 1, item 2
29 CFR 1910.255(b)(4) · Resistance welding
Serious$3,200$3,200Jul 18, 2022Final
Citation 1, item 3
29 CFR 1910.255(b)(5) · Resistance welding
Serious$3,200$3,200Jul 18, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(1)

(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.

29 CFR 1910.255 · Resistance welding

29 CFR 1910.255(b)(4)

(4) Guarding. All press welding machine operations, where there is a possibility of the operator's fingers being under the point of operation, shall be effectively guarded by the use of a device such as an electronic eye safety circuit, two hand controls or protection similar to that prescribed for punch press operation, § 1910.217 of this part. All chains, gears, operating bus linkage, and belts shall be protected by adequate guards, in accordance with § 1910.219 of this part.

29 CFR 1910.255(b)(5)

(5) Shields. The hazard of flying sparks shall be, wherever practical, eliminated by installing a shield guard of safety glass or suitable fire-resistant plastic at the point of operation. Additional shields or curtains shall be installed as necessary to protect passing persons from flying sparks. (See § 1910.252(b)(2)(i)(C) of this part.)

Other fabricated pipe and pipe fitting manufacturing employers in Kentucky

Alert subscribers get notified of each newly cited employer in Kentucky the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.