OSHA SearchOSHA records by employer

National Filter Media Corporation: OSHA inspections and violations

Winthrop, Maine · All Other Miscellaneous General Purpose Machinery Manufacturing · NAICS 333999

1inspections
4citation items
$7,300current penalties
May 6, 2015last inspection

National Filter Media Corporation has one OSHA inspection on record in Maine.

OSHA opened it on May 6, 2015 after a complaint, in Winthrop.

From that inspection OSHA issued 4 citation items: 3 serious and 1 other-than-serious.

OSHA proposed $14,960 in penalties. After settlements and reviews the total is $7,300, down 51%.

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. National Filter Media Corporation averages $7,300 over 1 cited inspection in that time.

National Filter Media Corporation also files yearly injury logs with OSHA, summarized below.

National Filter Media Corporation: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Maine · latest 90 days of OSHA records

33employers cited

Get notified the morning OSHA posts each new citation in Maine: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maine

Checking a subcontractor, a client or your own company? Watch National Filter Media Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340615129 OPENED MAY 6, 2015Closed

Complaint · Partial · Safety · 45 employees at the site · Closed May 20, 2016

12 Winada Drive, Winthrop, ME 04364 · All Other Miscellaneous General Purpose Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$4,675$2,800May 26, 2015Final
Citation 1, item 3
29 CFR 1910.242(b) · Hand and power tools
Serious$3,740$2,244May 26, 2015Final
Citation 1, item 4
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$3,740$2,256May 26, 2015Final
Citation 2, item 1
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$2,805$0May 26, 2015Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2019, the Winthrop site logged 0 recordable injuries or illnesses among about 27 workers: 0.0 per 100 full-time workers, against a median of 1.9 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
NFM Parts Maine
Winthrop · 2019
27 000.01.9
NFM Maine
Winthrop · 2019
27 103.91.9

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(1)

(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.242(b)

(b) Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment.

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.252(b)(2)(iii)

(iii) Protection from arc welding rays. Where the work permits, the welder should be enclosed in an individual booth painted with a finish of low reflectivity such as zinc oxide (an important factor for absorbing ultraviolet radiations) and lamp black, or shall be enclosed with noncombustible screens similarly painted. Booths and screens shall permit circulation of air at floor level. Workers or other persons adjacent to the welding areas shall be protected from the rays by noncombustible or flameproof screens or shields or shall be required to wear appropriate goggles.

29 CFR 1910.305 · Electrical wiring methods

Other all other miscellaneous general purpose machinery manufacturing employers in Maine

Alert subscribers get notified of each newly cited employer in Maine the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.