OSHA SearchOSHA records by employer

National Metal Processing Inc: OSHA inspections and violations

Richmond, Kentucky · Metal Heat Treating · NAICS 332811

7inspections
17citation items
$3,500current penalties
Aug 18, 2015last inspection

Since 1984, OSHA inspectors have visited National Metal Processing Inc in Kentucky 7 times.

The most recent inspection opened on Aug 18, 2015 as a planned inspection, in Richmond.

In all, OSHA issued 17 citation items: 6 serious and 11 other-than-serious.

The penalties, $3,500 in total, stand where OSHA first set them.

The rule cited most here is 1910.134 (respiratory protection), 5 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. National Metal Processing Inc averages $3,500 across 1 cited inspection.

National Metal Processing Inc also files yearly injury logs with OSHA, summarized below.

National Metal Processing Inc: OSHA citation items per year, 1984 to 2015
Citation items per year, by inspection date.

Kentucky · latest 90 days of OSHA records

180employers cited

Get notified the morning OSHA posts each new citation in Kentucky: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Kentucky

Checking a subcontractor, a client or your own company? Watch National Metal Processing Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340860105 OPENED AUG 18, 2015Closed

Planned · Complete · Safety · 22 employees at the site · Closed Apr 25, 2016

450 N Estill Ave, Richmond, KY 40475 · Metal Heat Treating · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(e)(2)(ii) · Respiratory protection
Serious$1,750$1,750Nov 23, 2015Final
Citation 1, item 1b
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$0$0Nov 23, 2015Final
Citation 1, item 1c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Nov 23, 2015Final
Citation 1, item 1d
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Serious$0$0Nov 23, 2015Final
Citation 1, item 1e
29 CFR 1910.134(k) · Respiratory protection
Serious$0$0Nov 23, 2015Final
Citation 1, item 2
29 CFR 1910.179(l)(3)(iii) · Overhead and gantry cranes
Serious$1,750$1,750Nov 23, 2015Final
Citation 2, item 1
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Other-than-serious$0$0Nov 23, 2015Final
Citation 2, item 2
29 CFR 2.310(1)(1)
Other-than-serious$0$0Nov 23, 2015Final

Inspection 126874924 OPENED MAY 30, 1996Closed

Planned · Complete · Safety · 27 employees at the site · Closed Jun 3, 1996

P O Box 280 N Estill Ave, Richmond, KY 40475 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 126875624 OPENED FEB 1, 1996Closed

Planned · Complete · Health · 28 employees at the site · Closed Aug 29, 1996

P O Box 280 N Estill Ave, Richmond, KY 40475 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Jun 12, 1996Closed
Citation 1, item 2 Other-than-serious$0$0Jun 12, 1996Closed
Citation 1, item 3 Other-than-serious$0$0Jun 12, 1996Closed
Citation 1, item 4 Other-than-serious$0$0Jun 12, 1996Closed

Inspection 104318191 OPENED AUG 2, 1990Closed

Planned · Complete · Safety · 30 employees at the site · Closed Aug 30, 1990

450 N. Estill Ave., Richmond, KY 40475 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.252(b)(4)(ixc) · Welding fire safety
Other-than-serious$0$0Aug 27, 1990Closed
Citation 1, item 2
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Aug 27, 1990Closed

Inspection 2799492 OPENED SEP 21, 1987Closed

Planned · Complete · Safety · 28 employees at the site · Closed Oct 13, 1987

P O Box 280 N Estill Ave, Richmond, KY 40475 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(q)(2) · Exit routes
Other-than-serious$0$0Sep 25, 1987Closed
Citation 1, item 2
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Sep 25, 1987Closed

Inspection 559336 OPENED MAR 8, 1984Closed

Planned · Partial · Health · 39 employees at the site · Closed Mar 30, 1984

450 N Estill Ave, Richmond, KY 40475 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Mar 27, 1984Closed

Inspection 558098 OPENED FEB 22, 1984Closed

Planned · Complete · Safety · 39 employees at the site · Closed Mar 9, 1984

450 N Estill Ave, Richmond, KY 40475 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Richmond site logged 0 recordable injuries or illnesses among about 20 workers: 0.0 per 100 full-time workers, against a median of 3.2 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
National Metal Processing, Inc.
Richmond · 2023
20 000.03.2

Included with any plan: 3 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(e)(2)(ii)

(ii) The medical evaluation shall obtain the information requested by the questionnaire in Sections 1 and 2, part A of appendix C of this section.

29 CFR 1910.134(f)(1)

(1) Normal breathing. In a normal standing position, without talking, the subject shall breathe normally.

29 CFR 1910.134(f)(2)

(2) Deep breathing. In a normal standing position, the subject shall breathe slowly and deeply, taking caution so as not to hyperventilate.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

29 CFR 1910.94 · Ventilation

29 CFR 1910.95 · Noise

Other metal heat treating employers in Kentucky

Alert subscribers get notified of each newly cited employer in Kentucky the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.