National Technical Systems, Inc. has 10 OSHA inspections on record in California, the first in 1990.
OSHA's last visit started on May 28, 2021 after a fatality or catastrophe, in Fullerton, and the case has not closed yet.
Across those inspections OSHA issued 29 citation items: 1 serious and 28 other-than-serious.
OSHA proposed $23,540 in penalties. After settlements and reviews the total is $6,195, down 74%.
For context, across all professional services employers the median penalty per cited inspection since 2015 is $1,821. National Technical Systems, Inc. averages $185 over 1 cited inspection in that time.
1 inspection on this page followed a fatal incident.
National Technical Systems, Inc. also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
California · latest 90 days of OSHA records
1,117employers cited
Get notified the morning OSHA posts each new citation in California: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch National Technical Systems, Inc. and get notified the morning OSHA posts a new citation for it.
Incident on May 27, 2021 (fatal): Employee is killed after explosion, possible smoke inhalatio
At 9:05 a.m. on May 27, 2021, an employee who worked as a contract Engineering Associate for a testing laboratory died from undetermined causes related to an explosion and fire, possibly smoke inhalation. The employee worked for a contract provider of environmental simulation testing, inspection, and certification services who operated amplifiers, oscilloscopes, spectrum analyzers, signal generators, and pulse voltage meters. The employee was in the process of testing a C-130 Modular Airborne Fire Fighting Systems (MAFFS) part. The unspecified part was owned by another entity and was placed within the contractor's test chambers at which time an Emission of Radio Frequency (RF) Energy test was scheduled. The employee had been working with Coworker #2 and Coworker #3, both whose occupations were unknown, and their roles not specified in the narrative. An explosion occured during the testing involving a compressor and resulting in a fire and heavy smoke. The area was evacuated and the Fire Department instructed everyone not to return.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 2
29 CFR 5194(E)(1)(A)
Other-than-serious
$280
$185
Oct 22, 2021
Final
Inspection 314858648 OPENED JAN 25, 2011Closed
Accident · Partial · Safety · 20 employees at the site · Closed May 14, 2011
Incident on Jan 18, 2011: Employee suffers fractures after falling off a-frame ladder
On January 18, 2011 Employee #1 started working on that day at 12:00 a.m. and th e accident occurred at 7:00 a.m.. The thermal test in chamber C-7 required sever al days to complete, and the accident occurred on the second day of the test. Li quid nitrogen was used to cool parts inside chamber to -300 F degrees, and a hea ter inside the chamber to heat parts to +300 F degrees. Prior to the accident oc curring, Employee #1 observed some nitrogen gas leak from the top of chamber, an d all 3 clamps at the top of chamber were not secured down. After confirming wit h the test engineer to bring chamber back to room temperature, and all 3 clamps needed to be secure at the top; Employee #1 used 8 foot A-frame ladder to access clamps at the top of chamber. Employee #1 fell off ladder while he was standing on the 6th rung of ladder. Employee #1 did not remember anything about the acci dent and why he fell. There were no actual witnesses to the accident. Employee # 1 was taken to Centinela Hospital and was hospitalized for 3 days. Employee #1 s uffered broken right wrist and shoulder pain.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 1
29 CFR 3203 A07 D
Other-than-serious
$280
$280
Apr 19, 2011
Closed
Inspection 314822776 OPENED NOV 2, 2010Closed
Unprogrammed related · Partial · Safety · 85 employees at the site · Closed Mar 15, 2011
Incident on Mar 19, 2002: Employee's foot amputated after tank rolled over it
At approximately 5:20 p.m. on March 19, 2002, Employee #1 of National Technical System instructed a forklift operator to lift a metal tank of 41 in., width by 4 1 in., depth by 75 in., height size with casters using a forklift to place the t ank on a concrete block of 40 in., width by 42 in., depth by 23.5 in., height si ze. When the tank was placed on the block, it started to roll off the block to w here Employee #1 was standing. Employee #1 tried to stop the tank from falling o ff, but the tank was too heavy for him. He then attempted to move away to avoid being hit by the tank, but the falling tank landed on Employee #1's right foot a nd crushed the front half. Employee #1 was hospitalized for amputation.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2017, the Santa Clarita site logged 4 recordable injuries or illnesses among about 90 workers: 4.5 per 100 full-time workers, against a median of 0.0 for its industry. Those cases cost 14 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Santa Clarita Lab
Santa Clarita · 2017
90
4
1
4.5
0.0
Fullerton Lab
Fullerton · 2017
79
3
0
3.6
0.0
LAX Lab
Los Angeles · 2017
21
1
0
4.2
0.0
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
Alert subscribers get notified of each newly cited employer in California the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.