OSHA SearchOSHA records by employer

Nations Renovations, LLC: OSHA inspections and violations

Altoona, Iowa · Roofing Contractors · NAICS 238160

1inspections
3citation items
$1,350current penalties
Sep 23, 2015last inspection

OSHA inspectors have visited Nations Renovations, LLC in Iowa one time.

It opened on Sep 23, 2015 as a planned inspection, in Altoona.

In all, OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

The penalties, $1,350 in total, stand where OSHA first set them.

The rule cited most here is 1926.1053 (ladders in construction), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Nations Renovations, LLC averages $1,350 across 1 cited inspection.

Nations Renovations, LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Iowa · latest 90 days of OSHA records

64employers cited

Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Iowa

Checking a subcontractor, a client or your own company? Watch Nations Renovations, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340940196 OPENED SEP 23, 2015Closed

Planned · Complete · Safety · 20 employees at the site · Closed Jul 20, 2016

215 Adventurland Drive Nw, Altoona, IA 50009 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(a)(1)(ii) · Ladders in construction
Serious$750$750Oct 8, 2015Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$600$600Oct 8, 2015Final
Citation 2, item 1
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Oct 8, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(a)(1)(ii)

(ii) Each portable ladder that is not self-supporting: At least four times the maximum intended load, except that each extra-heavy-duty type 1A metal or plastic ladders shall sustain at least 3.3 times the maximum intended load. The ability of a ladder to sustain the loads indicated in this paragraph shall be determined by applying or transmitting the requisite load to the ladder in a downward vertical direction when the ladder is placed at an angle of 75 1/2 degrees from the horizontal. Ladders built and tested in conformance with the applicable provisions of appendix A will be deemed to meet this requirement.

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

Other roofing contractors employers in Iowa

Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.