OSHA SearchOSHA records by employer

Nationwide Homes: OSHA inspections and violations

Martinsville, Virginia · Prefabricated Wood Building Manufacturing · NAICS 321992

19inspections
101citation items
$402,830current penalties
Jul 17, 2023last inspection

OSHA has inspected Nationwide Homes 19 times in Virginia since 1974.

The latest one began on Jul 17, 2023 after a complaint, in Martinsville.

Those inspections ended with 101 citation items: 75 serious and 26 other-than-serious.

Penalties were first proposed at $433,034 and now stand at $402,830, 7% lower after settlements or reviews.

Electrical wiring methods comes up most often in these citations: 14 items under 1910.305.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Nationwide Homes averages $97,912 (4 cited inspections).

Nationwide Homes: OSHA citation items per year, 1974 to 2023
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

248employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Nationwide Homes and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346835135 OPENED JUL 17, 2023Closed

Complaint · Partial · Safety · 185 employees at the site · Closed Aug 9, 2023

1100 Rives Rd, Martinsville, VA 24112 · Prefabricated Wood Building Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346935240 OPENED MAR 31, 2023Closed

Complaint · Partial · Safety · 195 employees at the site · Closed Aug 28, 2023

1100 Rives Rd, Martinsville, VA 24112 · Prefabricated Wood Building Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346372436 OPENED DEC 5, 2022Open

Accident · Partial · Safety · 205 employees at the site · Open

1100 Rives Rd, Martinsville, VA 24112 · Prefabricated Wood Building Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 16VAC25-60-120
Serious$14,270$14,270Dec 30, 2022Contested
Citation 1, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$7,840$7,840Dec 30, 2022Contested

Inspection 345837587 OPENED MAR 15, 2022Open

Planned · Complete · Safety · 198 employees at the site · Open

1100 Rives Rd, Martinsville, VA 24112 · Prefabricated Wood Building Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · Walking-working surfaces
Serious$5,910$5,910Sep 13, 2022Contested
Citation 1, item 2
29 CFR 1910.22(b) · Walking-working surfaces
Serious$8,215$8,215Sep 13, 2022Contested
Citation 1, item 3
29 CFR 1910.23(b)(8) · Ladders in general industry
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 4a Serious$6,920$6,920Sep 13, 2022Contested
Citation 1, item 4b Serious$0$0Sep 13, 2022Contested
Citation 1, item 5
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 6
29 CFR 1910.28(b)(3)(ii) · Fall protection in general industry
Serious$6,920$6,920Sep 13, 2022Contested
Citation 1, item 7
29 CFR 1910.28(b)(11)(ii) · Fall protection in general industry
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 8
29 CFR 1910.37(a)(3) · Exit routes
Serious$4,755$4,755Sep 13, 2022Contested
Citation 1, item 9a
29 CFR 1910.37(b)(2) · Exit routes
Serious$4,755$4,755Sep 13, 2022Contested
Citation 1, item 9b
29 CFR 1910.37(b)(4) · Exit routes
Serious$0$0Sep 13, 2022Contested
Citation 1, item 9c
29 CFR 1910.37(b)(5) · Exit routes
Serious$0$0Sep 13, 2022Contested
Citation 1, item 9d
29 CFR 1910.37(b)(6) · Exit routes
Serious$0$0Sep 13, 2022Contested
Citation 1, item 10a
29 CFR 1910.106(b)(6) · Flammable liquids
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 10b
29 CFR 1910.106(d)(5)(i) · Flammable liquids
Serious$0$0Sep 13, 2022Contested
Citation 1, item 10c
29 CFR 1910.106(d)(7)(iii) · Flammable liquids
Serious$0$0Sep 13, 2022Contested
Citation 1, item 11
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$10,745$10,745Sep 13, 2022Contested
Citation 1, item 12
29 CFR 1910.135(a)(1) · Head protection
Serious$10,745$10,745Sep 13, 2022Contested
Citation 1, item 13
29 CFR 1910.140(c)(20) · Personal fall protection systems
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 14a
29 CFR 1910.147(c)(5)(ii) · Lockout/tagout
Serious$4,755$4,755Sep 13, 2022Contested
Citation 1, item 14b Serious$0$0Sep 13, 2022Contested
Citation 1, item 15a
29 CFR 1910.147(d)(4)(ii) · Lockout/tagout
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 15b
29 CFR 1910.147(e)(3) · Lockout/tagout
Serious$0$0Sep 13, 2022Contested
Citation 1, item 16a
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Serious$5,910$5,910Sep 13, 2022Contested
Citation 1, item 16b
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Serious$0$0Sep 13, 2022Contested
Citation 1, item 16c
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Serious$0$0Sep 13, 2022Contested
Citation 1, item 17
29 CFR 1910.176(b) · Material storage and aisles
Serious$6,920$6,920Sep 13, 2022Contested
Citation 1, item 18
29 CFR 1910.179(g)(1)(v) · Overhead and gantry cranes
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 19
29 CFR 1910.179(h)(4) · Overhead and gantry cranes
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 20
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 21
29 CFR 1910.212(a)(5) · Machine guarding
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 22
29 CFR 1910.213(a)(9) · Woodworking machinery
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 23
29 CFR 1910.213(f)(1) · Woodworking machinery
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 24
29 CFR 1910.213(l)(2) · Woodworking machinery
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 25
29 CFR 1910.213(m)(1) · Woodworking machinery
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 26
29 CFR 1910.213(p)(4) · Woodworking machinery
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 27a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 27b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Sep 13, 2022Contested
Citation 1, item 28
29 CFR 1910.242(a) · Hand and power tools
Serious$4,755$4,755Sep 13, 2022Contested
Citation 1, item 29a
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 29b
29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting
Serious$0$0Sep 13, 2022Contested
Citation 1, item 29c
29 CFR 1910.253(b)(4)(i) · Gas welding and cutting
Serious$0$0Sep 13, 2022Contested
Citation 1, item 30
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 31
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 32
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Serious$4,755$4,755Sep 13, 2022Contested
Citation 1, item 33
29 CFR 1910.305(a)(2)(vii) · Electrical wiring methods
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 34
29 CFR 1910.305(a)(2)(ix) · Electrical wiring methods
Serious$4,755$4,755Sep 13, 2022Contested
Citation 1, item 35
29 CFR 1910.305(a)(2)(x) · Electrical wiring methods
Serious$4,755$4,755Sep 13, 2022Contested
Citation 1, item 36
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 37
29 CFR 1910.305(b)(3)(ii) · Electrical wiring methods
Serious$4,755$4,755Sep 13, 2022Contested
Citation 1, item 38
29 CFR 1910.305(d)(2) · Electrical wiring methods
Serious$6,920$6,920Sep 13, 2022Contested
Citation 1, item 39
29 CFR 1910.305(e)(1) · Electrical wiring methods
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 40
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 41
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 42
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 43
29 CFR 1910.307(c)(2)(i) · Hazardous (classified) locations
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 44a
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Serious$9,085$9,085Sep 13, 2022Contested
Citation 1, item 44b
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Serious$0$0Sep 13, 2022Contested
Citation 2, item 1
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$0$0Sep 13, 2022Contested
Citation 2, item 2
29 CFR 1910.1200(f)(6) · Hazard communication
Other-than-serious$0$0Sep 13, 2022Contested
Citation 2, item 3
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Sep 13, 2022Contested

Inspection 344953591 OPENED OCT 1, 2020Closed

Referral · Partial · Safety · 200 employees at the site · Closed Jan 21, 2021

1100 Rives Rd, Martinsville, VA 24112 · Prefabricated Wood Building Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Sep 29, 2020: Employee amputates finger in saw blade

At 3:40 p.m. on September 29, 2020, an employee was setting a piece of 2 by 4 stock to cut. The employee's right hand was pulled into the delta radial arm saw blade, and the index finger was amputated by the saw blade. The employee was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$13,277$0Dec 2, 2020Final

Inspection 344362603 OPENED OCT 8, 2019Closed

Referral · Partial · Safety · 3 employees at the site · Closed Aug 24, 2020

11462 Watkins Rd, Rockville, VA 23146 · Prefabricated Wood Building Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Oct 5, 2019: Employee fractures sternum and ribs in fall from ladder

At 1:00 p.m. on October 5, 2019, an employee was carrying a pack of shingles while climbing a ladder. While placing the shingles on the roof, he lost his balance and fell to the ground. As he was falling, he struck against a wooden support beam. The employee was hospitalized for treatment of a fractured sternum and two fractured ribs.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$6,065$4,000Jan 3, 2020Final
Citation 1, item 1b
29 CFR 1926.1053(b)(6) · Ladders in construction
Serious$6,065$0Jan 3, 2020Final
Citation 1, item 3
29 CFR 1926.1053(b)(22) · Ladders in construction
Serious$13,047$13,000Jan 3, 2020Final

Inspection 341201275 OPENED JAN 26, 2016Closed

Referral · Partial · Safety · 145 employees at the site · Closed Feb 8, 2016

1100 Rives Rd, Martinsville, VA 24112 · Prefabricated Wood Building Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315066639 OPENED OCT 27, 2010Closed

Planned · Complete · Safety · 110 employees at the site · Closed Sep 30, 2011

1100 Rives Road, Martinsville, VA 24112 · Prefabricated Wood Building Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$1,155$693Nov 23, 2010Closed
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Nov 23, 2010Closed
Citation 2, item 2
29 CFR RVSG0050 A
Other-than-serious$0$0Nov 23, 2010Closed
11 older inspections

Inspection 305358277 OPENED SEP 5, 2002Closed

Planned · Partial · Safety · 450 employees at the site · Closed Sep 5, 2002

1100 Rives Road, Martinsville, VA 24112 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 304538291 OPENED AUG 16, 2001Closed

Planned · Partial · Safety · 350 employees at the site · Closed Aug 16, 2001

1100 Rives Road, Martinsville, VA 24112 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 303903967 OPENED NOV 13, 2000Closed

Planned · Partial · Safety · 5 employees at the site · Closed Apr 4, 2001

3301 Peters Creek Road, Roanoke, VA 24019 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$4,000$4,000Dec 8, 2000Closed

Inspection 125451401 OPENED AUG 19, 1998Closed

Planned · Complete · Safety · 425 employees at the site · Closed Sep 29, 1998

1100 Rives Road, Martinsville, VA 24112 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(b)(3) · Woodworking machinery
Serious$1,300$762Sep 11, 1998Closed
Citation 1, item 2a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$1,625$700Sep 11, 1998Closed
Citation 1, item 2b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Sep 11, 1998Closed
Citation 1, item 3a
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$1,625$700Sep 11, 1998Closed
Citation 1, item 3b
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Serious$0$0Sep 11, 1998Closed
Citation 1, item 4a
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$975$600Sep 11, 1998Closed
Citation 1, item 4b
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$0$0Sep 11, 1998Closed
Citation 2, item 1
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Sep 11, 1998Closed

Inspection 126644731 OPENED DEC 4, 1997Closed

Complaint · Partial · Health · 375 employees at the site · Closed Feb 5, 1998

1100 Rives Road, Martinsville, VA 24112 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1101(k)(2)(i) · Asbestos in construction
Other-than-serious$0$0Jan 27, 1998Closed
Citation 1, item 2
29 CFR 1926.1101(k)(6) · Asbestos in construction
Other-than-serious$0$0Jan 27, 1998Closed
Citation 1, item 3
29 CFR 1926.1101(l)(2) · Asbestos in construction
Other-than-serious$0$0Jan 27, 1998Closed

Inspection 126605476 OPENED AUG 21, 1996Closed

Complaint · Partial · Safety · 394 employees at the site · Closed Oct 27, 1998

1100 Rives Road, Martinsville, VA 24112 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$2,625$0Sep 16, 1996Final
Citation 1, item 2
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$4,500$2,500Sep 16, 1996Final
Citation 1, item 3
29 CFR 1910.23(e)(3)(iv) · Guarding floor and wall openings and holes
Serious$1,875$975Sep 16, 1996Final

Inspection 18743898 OPENED AUG 19, 1987Closed

Planned · Complete · Safety · 385 employees at the site · Closed Oct 22, 1987

1100 Rives Road, Martinsville, VA 24112 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Sep 8, 1987Closed
Citation 1, item 2
29 CFR 1910.23(e)(4) · Guarding floor and wall openings and holes
Other-than-serious$0$0Sep 8, 1987Closed
Citation 1, item 3
29 CFR 1910.106(d)(7)(iii) · Flammable liquids
Other-than-serious$0$0Sep 8, 1987Closed
Citation 1, item 4
29 CFR 1910.106(f)(6) · Flammable liquids
Other-than-serious$0$0Sep 8, 1987Closed
Citation 1, item 5
29 CFR 1910.305(g)(1)(i) · Electrical wiring methods
Other-than-serious$0$0Sep 8, 1987Closed
Citation 1, item 6
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Sep 8, 1987Closed
Citation 1, item 7
29 CFR 1910.1200(g)(2)(v) · Hazard communication
Other-than-serious$0$0Sep 8, 1987Closed
Citation 1, item 8
29 CFR 1910.1200(g)(2)(vii) · Hazard communication
Other-than-serious$0$0Sep 8, 1987Closed
Citation 1, item 9
29 CFR 1910.1200(g)(2)(xi) · Hazard communication
Other-than-serious$0$0Sep 8, 1987Closed

Inspection 15217888 OPENED APR 9, 1984Closed

Planned · Partial · Safety · 318 employees at the site · Closed Apr 13, 1984

1100 Rives Rd, Martinssville, VA 24115 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 12598330 OPENED JUL 11, 1983Closed

Planned · Records only · Safety · 318 employees at the site · Closed Jul 11, 1983

1100 Rives Rd, Martinsville, VA 24112 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 12394987 OPENED JAN 3, 1975Closed

Follow-up · Partial · Safety · 235 employees at the site · Closed Mar 10, 1984

1100 Rives Road Po Box 5511, Martinsville, VA 24112 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 12394920 OPENED NOV 26, 1974Closed

Planned · Complete · Safety · 235 employees at the site · Closed Dec 23, 1974

1100 Rives Road P O Box 5511, Martinsville, VA 24112 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.169(b)(3)(iv) · Air receivers
Other-than-serious$40$40Nov 27, 1974Closed
Citation 1, item 2
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Other-than-serious$35$35Nov 27, 1974Closed
Citation 1, item 3
29 CFR 1910.213(h)(1) · Woodworking machinery
Other-than-serious$60$60Nov 27, 1974Closed
Citation 1, item 4
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$45$45Nov 27, 1974Closed
Citation 1, item 5
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0Nov 27, 1974Closed
Citation 1, item 6 Other-than-serious$35$35Nov 27, 1974Closed
Citation 1, item 7
29 CFR 1910.179(j)(2)(iv) · Overhead and gantry cranes
Other-than-serious$35$35Nov 27, 1974Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(5)(i)

(5) Storage inside building—(i) Egress. Flammable liquids, including stock for sale, shall not be stored so as to limit use of exits, stairways, or areas normally used for the safe egress of people.

29 CFR 1910.106(d)(7)(iii)

(iii) Open flames and smoking. Open flames and smoking shall not be permitted in flammable liquid storage areas.

29 CFR 1910.106(f)(6)

(6) Sources of ignition. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be handled, drawn, or dispensed where flammable vapors may reach a source of ignition. Smoking shall be prohibited except in designated localities. “No Smoking” signs shall be conspicuously posted where hazard from flammable liquid vapors is normally present.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.135 · Head protection

29 CFR 1910.140 · Personal fall protection systems

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.169 · Air receivers

29 CFR 1910.176 · Material storage and aisles

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.23 · Ladders in general industry

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.25 · Stairways

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.307 · Hazardous (classified) locations

29 CFR 1910.309

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.37 · Exit routes

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1101 · Asbestos in construction

29 CFR 1926.501 · Fall protection in construction

Other prefabricated wood building manufacturing employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.