OSHA SearchOSHA records by employer

Naughton & Daly Contractors: OSHA inspections and violations

Henrietta, New York · Drywall and Insulation Contractors · NAICS 238310

5inspections
10citation items
$4,775current penalties
Jun 10, 2022last inspection

Since 1989, OSHA inspectors have visited Naughton & Daly Contractors in New York 5 times.

The most recent inspection opened on Jun 10, 2022 as a planned inspection, in Rochester.

In all, OSHA issued 10 citation items: 8 serious and 2 other-than-serious.

The proposed penalties came to $8,655; today they stand at $4,775, 45% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Naughton & Daly Contractors averages $1,500 across 1 cited inspection.

Naughton & Daly Contractors: OSHA citation items per year, 1989 to 2022
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

360employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Naughton & Daly Contractors and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346029994 OPENED JUN 10, 2022Closed

Planned · Partial · Safety · 3 employees at the site · Closed Sep 21, 2022

2750 Monroe Avenue, Rochester, NY 14618 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$2,395$1,500Aug 10, 2022Final

Inspection 335292835 OPENED JUL 19, 2012Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jan 22, 2013

2301 Westside Drive, Rochester, NY 14624 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$1,700$1,000Aug 29, 2012Final
Citation 1, item 2
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Other-than-serious$1,700$0Aug 29, 2012Final

Inspection 313065385 OPENED APR 2, 2009Closed

Planned · Partial · Safety · 4 employees at the site · Closed May 8, 2009

900 Jefferson Road, Henrietta, NY 14623 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$510$510Apr 15, 2009Closed

Inspection 114091481 OPENED OCT 20, 1997Closed

Referral · Complete · Safety · 4 employees at the site · Closed Dec 5, 1997

Professional Business Park, Calkins Road, Henrietta, NY 14623 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$750$525Oct 31, 1997Closed
Citation 1, item 2
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$750$525Oct 31, 1997Closed
Citation 1, item 3
29 CFR 1926.454(a)(1) · Scaffold training
Serious$450$315Oct 31, 1997Closed

Inspection 106918022 OPENED JAN 31, 1989Closed

Planned · Complete · Safety · 4 employees at the site · Closed Feb 24, 1989

395 Summit Point Drive, Henrietta, NY 14623 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$200$200Feb 10, 1989Closed
Citation 1, item 2
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$200$200Feb 10, 1989Closed
Citation 2, item 1
29 CFR 1926.150(c)(1)(vi) · Fire protection
Other-than-serious$0$0Feb 10, 1989Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(vi)

(vi) A fire extinguisher, rated not less than 10B, shall be provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas are being used on the jobsite. This requirement does not apply to the integral fuel tanks of motor vehicles.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

Other drywall and insulation contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.