OSHA SearchOSHA records by employer

Nava Construction Company, LLC: OSHA inspections and violations

Charlotte, North Carolina · Siding Contractors · NAICS 238170

2inspections
4citation items
$6,900current penalties
Jan 6, 2020last inspection

OSHA has inspected Nava Construction Company, LLC 2 times in North Carolina since 2018.

The latest one began on Jan 6, 2020 as a planned inspection, in Apex.

Those inspections ended with 4 citation items: 4 serious.

Penalties were first proposed at $6,900 and still stand at $6,900.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Nava Construction Company, LLC averages $3,450 (2 cited inspections).

Nava Construction Company, LLC: OSHA citation items per year, 2018 to 2020
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

228employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Nava Construction Company, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344541545 OPENED JAN 6, 2020Closed

Planned · Complete · Health · 3 employees at the site · Closed Jun 9, 2020

1028 Blackpool Ct., Apex, NC 27502 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$600$600Jan 29, 2020Final

Inspection 343448619 OPENED SEP 5, 2018Closed

Planned · Partial · Safety · 4 employees at the site · Closed Feb 28, 2024

8631 Reames Rd, Charlotte, NC 28216 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$2,100$2,100Dec 3, 2018Final
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,100$2,100Dec 3, 2018Final
Citation 1, item 3
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$2,100$2,100Dec 3, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(5)(ii)

(ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.452 · Rules for each type of scaffold

Other siding contractors employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.