1inspections
4citation items
$3,900current penalties
Jun 1, 2022last inspection

NC Dot Safety and Risk Management Maintenance has one OSHA inspection on record in North Carolina.

OSHA opened it on Jun 1, 2022 as a planned inspection, in Winston Salem.

From that inspection OSHA issued 4 citation items: 1 serious and 3 other-than-serious.

OSHA proposed $6,500 in penalties. After settlements and reviews the total is $3,900, down 40%.

Most often, OSHA cited 1910.303, electrical equipment, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. NC Dot Safety and Risk Management Maintenance averages $3,900 over 1 cited inspection in that time.

NC Dot Safety and Risk Management Maintenance: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

226employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch NC Dot Safety and Risk Management Maintenance and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346000391 OPENED JUN 1, 2022Closed

Planned · Complete · Safety · State government · 40 employees at the site · Closed Aug 12, 2022

300 Craft Drive, Winston Salem, NC 27105 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$3,250$1,950Jun 29, 2022Final
Citation 1, item 2
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Other-than-serious$3,250$1,950Jun 29, 2022Final
Citation 2, item 1
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Jun 29, 2022Final
Citation 2, item 2
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Jun 29, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(e)(2)

(2) Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section shall be visually inspected monthly.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(1)

(b) Examination, installation, and use of equipment—(1) Examination. Electric equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined using the following considerations:

29 CFR 1910.303(g)(2)(i)

(2) Guarding of live parts. (i) Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means:

29 CFR 1910.304 · Grounding and circuit protection

Other highway, street, and bridge construction employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.