Nci Group, Inc.: OSHA inspections and violations

Byram, Mississippi · Fabricated Structural Metal Manufacturing · NAICS 332312

2inspections
4citation items
$2,596current penalties
Apr 24, 2019last inspection

Nci Group, Inc. has 2 OSHA inspections on record in Mississippi, the first in 2013.

OSHA's last visit started on Apr 24, 2019 on a referral, in Byram.

Across those inspections OSHA issued 4 citation items: 1 serious and 3 other-than-serious.

OSHA proposed $3,289 in penalties. After settlements and reviews the total is $2,596, down 21%.

Most often, OSHA cited 1910.147, lockout/tagout (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Nci Group, Inc. averages $596 over 1 cited inspection in that time.

It reported 2 severe injuries to OSHA since 2015.

Nci Group, Inc.: OSHA citation items per year, 2013 to 2019
Citation items per year, by inspection date.

Mississippi · latest 90 days of OSHA records

16employers cited

Get notified the morning OSHA posts each new citation in Mississippi: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Mississippi

Checking a subcontractor, a client or your own company? Watch Nci Group, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Nci Group, Inc. at 14 sites in 10 states. Together they've had 27 inspections and $125,772 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 14 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 343958096 OPENED APR 24, 2019Closed

Referral · Partial · Safety · 105 employees at the site · Closed Jun 26, 2019

951 Prisock Road, Byram, MS 39272 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Apr 18, 2019: Employee's fingers are amputated by coil-coating machine

At 7:00 a.m. on April 18, 2019, an employee was working for a manufacturer of fabricated structural metal. He was cleaning a Chemcoater coil-coating machine. The employee entered the perimeter fence around the machine and removed the guards to clean the rollers with the machine still running. After removing the guards, the employee placed his fingers near the rollers. The fingers became got caught between the top and bottom rollers. The small finger, ring finger, and and index finger on the employee's right hand were amputated. The employee was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$994$596Jun 4, 2019Final

Inspection 339271041 OPENED AUG 8, 2013Closed

Referral · Partial · Safety · 104 employees at the site · Closed Jul 16, 2014

951 Prisock Road, Byram, MS 39272 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.22(c) · General requirements
Serious$2,295$2,000Sep 26, 2013Final
Citation 2, item 1
29 CFR 1910.146(k)(2)(iv) · Permit-required confined spaces
Other-than-serious$0$0Sep 26, 2013Final
Citation 2, item 2
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Other-than-serious$0$0Sep 26, 2013Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Jun 22, 2019, Byram: Amputation · amputations · fingertip(s)

A maintenance employee was completing work on a metal shaft that was in a milling machine. The employee turned the milling equipment on and was polishing the end of the rotating shaft with a piece of emery cloth. During the process, his glove or the emery cloth wrapped around the rotating shaft, pulling his hand onto the shaft. He suffered a dislocation to his left little finger, as well as an…

Apr 18, 2019, Byram: Hospitalization, amputation · amputations · finger(s), fingernail(s), n.e.c.

An employee was attempting to clean the applicator rollers on a coil coating machine when the employee's right fingers were caught between the in-going rollers. The employee was hospitalized and sustained amputations to the right small, ring, and middle fingers.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.146(k)(2)(iv)

(iv) Ensure that affected employees practice making permit space rescues at least once every 12 months, by means of simulated rescue operations in which they remove dummies, manikins, or actual persons from the actual permit spaces or from representative permit spaces. Representative permit spaces shall, with respect to opening size, configuration, and accessibility, simulate the types of permit spaces from which rescue is to be performed.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.147(c)(6)(ii)

(ii) The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.

29 CFR 1910.22 · General requirements

Other fabricated structural metal manufacturing employers in Mississippi

Alert subscribers get notified of each newly cited employer in Mississippi the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.