OSHA SearchOSHA records by employer

Negrete Construction LLC: OSHA inspections and violations

Brunswick, Ohio · Finish Carpentry Contractors · NAICS 238350

1inspections
3citation items
$6,554current penalties
Feb 3, 2021last inspection

Negrete Construction LLC has one OSHA inspection on record in Ohio.

OSHA opened it on Feb 3, 2021 after a complaint, in Brunswick.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $9,363 in penalties. After settlements and reviews the total is $6,554, down 30%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Negrete Construction LLC averages $6,554 over 1 cited inspection in that time.

Negrete Construction LLC: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

273employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Negrete Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345132005 OPENED FEB 3, 2021Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Feb 17, 2022

3753 Center Rd, Brunswick, OH 44212 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$3,511$2,458Mar 11, 2021Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,341$1,639Mar 11, 2021Final
Citation 1, item 3
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$3,511$2,458Mar 11, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

Other finish carpentry contractors employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.