Nellson Nutraceutical, LLC: OSHA inspections and violations
Irwindale, California · All Other Miscellaneous Food Manufacturing · NAICS 311999
24inspections
83citation items
$315,105current penalties
Jun 4, 2024last inspection
OSHA has inspected Nellson Nutraceutical, LLC 24 times in California since 1999.
The latest one began on Jun 4, 2024 after an accident, in Anaheim; the case is still open.
Those inspections ended with 83 citation items: 35 serious, 3 repeat and 45 other-than-serious.
Penalties were first proposed at $451,750 and now stand at $315,105, 30% lower after settlements or reviews.
comes up most often in these citations: 2 items under 2340.23.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,874, and Nellson Nutraceutical, LLC averages $12,121 (7 cited inspections).
Nellson Nutraceutical, LLC also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
California · latest 90 days of OSHA records
1,111employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in California: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Nellson Nutraceutical, LLC and get notified the morning OSHA posts a new citation for it.
Incident on Aug 19, 2021: Employee injures fingers when caught in food packaging machi
At 11:30 a.m. on August 19, 2021, an employee working as a machine operator for a food supplement manufacturer was involved with cleaning the Line 17A packaging machine. The employee was using a brush, a spatula and wipes during cleaning. The employee was working with Coworker #1, a packer, who had been working at the other side of the line and had left the line at the time. The employee called Coworker #2, a mechanic, over to the line when she saw debris in the Teflon jaws section of the line. After the employee called Coworker #2 over to the line for a jamming problem, Coworker #3, another mechanic, came to assist. Coworker #2 instructed Coworker #3 to close the doors which guard the jaws at the other side of the line. Coworker #2 confirmed to the employee that there was debris and said he was going to clean it. The employee said that she would do it because it's part of her job. Coworker #2 closed the doors of the jaws and turned towards Coworker #3. The employee knew the mechanics were still working on the line and could not lockout/tagout the line while they were working. She still proceeded to clean by opening the doors which serve as an interlock, but which do not deenergize the line. She did not perform procedures for lockout/tagout which are required when cleaning. The mechanics heard the injured employee screaming and went to see what happened. She had caught her right hand between the jaws and was trying to pull her fingers out. The mechanics told her to wait until the jaws opened. They administered first aid once her hand was free. The employee was treated at a clinic for contusions, dislocations, lacerations and fractures to her middle and ring fingers for which she was hospitalized to undergo surgery.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 1
29 CFR 3203(A)(8)
Other-than-serious
$0
$0
Feb 9, 2022
Final
Inspection 344023049 OPENED MAY 20, 2019Closed
Accident · Partial · Safety · 450 employees at the site · Closed Jan 13, 2020
Incident on May 9, 2019: Employee amputates thumb after hitting button when distracte
At 1:45 p.m. on May 9, 2019, an employee was in the process of setting up a Berthel Line 17A horizontal packaging machine which is equipped with an interlocked door and an optional maintenance mode during which the interlock is rendered inactive. The employee was setting up the aluminum film while the machine was in the maintenance mode. The employee was jogging the machine with his left hand on the control panel button while using his right hand to pull scrap foil out of the machine. In the jog mode, moving parts in the machine normally stop as soon the hand is off the jog button. The employee reported that he took his left hand off the jog button before placing his right hand in the machine but his left hand accidentally slipped back onto the jog button when he was distracted by a coworker. The employee amputated half of his right thumb on the cutting knife when the machine cycled, requiring medical treatment. The employee was not hospitalized.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 1
29 CFR 3314(G)
Other-than-serious
$750
$475
Oct 8, 2019
Final
Citation 2, item 1
29 CFR 3314(D)
Serious
$18,000
$18,000
Oct 8, 2019
Final
Inspection 343646071 OPENED DEC 7, 2018Closed
Complaint · Partial · Safety · 200 employees at the site · Closed Jun 3, 2019
Incident on Jul 11, 2013: Employee loses finger while cleaning flow pump
On July 11, 2013, Employee #1 was cleaning a positive flow pump in Deck A of a p roduction area. Employee #1 used his right index finger to check for left over r esidue inside the wall of the pump's pipe when it contacted the rotating blade p ropeller inside the pump. The pump was on and had not been deenergized. Employee #1 suffered an amputation to his right index finger. He was admitted to a local hospital for surgery due to the incident. After the surgery, Employee #1 was re leased from the hospital.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 1
29 CFR 3314 J
Serious
$6,750
$540
Jan 7, 2014
Final
Citation 2, item 1
29 CFR 3314 C
Serious
$18,000
$18,000
Jan 7, 2014
Final
Inspection 312662463 OPENED NOV 5, 2009Closed
Accident · Partial · Safety · 162 employees at the site · Closed Jun 1, 2016
Incident on Mar 28, 2007: Employee's finger is amputated in machine
At approximately 5:23 p.m. on March 28, 2007, an employee was working in one of the mixing rooms where they use a pump to empty a drum of caramel into tubs. The drums are lined with plastic. The employee was emptying a barrel of caramel int o plastic tubs. The employee stated that there was a rubber part that got stuck in the piston and someone had turned on the machine when he was trying to get it unstuck and as a result part of his glove was missing because his finger was cu t. The employee was not hospitalized. In an interview Coworker #1 stated that th e plastic was caught below the pump. He stated that he turned it on very slowly and told the employee not to put his hand in there. He stated that when he turne d it on the employee wanted to pull the plastic out. Coworker #1 statement was c ontrary to Coworker #2's statement. Coworker #3 stated that Coworker #1 turned o n the machine and that's when the injury occurred. When asked if Coworker #1 tol d the employee not to put his hand there, he said "no" and Coworker #1 was the o ne who instructed the employee to put his hand there. The employee and Coworker #2 stated that they were not trained on what to do if the plastic got caught in the pump. Coworker #1 stated that "You just have to be careful. They told us if the machine is on not to put our hands in there." In reviewing the training reco rds, Coworker #1's name appear on the "Graco Pump Operating Procedure" dated Feb ruary 11, 2005, but the employee and Coworker #2's name were not listed.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 1
29 CFR 3314 J02
Serious
$18,000
$0
Aug 10, 2007
Final
Citation 2, item 1
29 CFR 3314 C
Serious
$18,000
$13,500
Aug 10, 2007
Final
Inspection 301335477 OPENED JUN 6, 2005Open
Accident · Partial · Safety · 700 employees at the site · Open
Incident on Jun 4, 2005: Employee's hand is amputated in machine rollers
On June 4, 2005, Employee #1, a temporary employee with Staffmark, was cleaning a pair of rolls in a caramel extruder in the Nellson Nutraceutical's production area. He was standing on a stepladder that was unstable due to uneven feet. With the hopper removed and the extruder turned off, he scraped caramel off a portio n of the extruder rolls. He then turned on the extruder to rotate the rolls to c ontinue the cleaning process. While the rolls were rotating, the ladder rocked. Employee #1 leaned forward to catch his balance. The spatula he was holding beca me caught at the in- running side of the rolls. His right hand was then crushed by revolving rolls. Employee #1 was hospitalized for an amputation of the hand.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 1
29 CFR 3272 B
Other-than-serious
$475
$175
Nov 22, 2005
Final
Citation 2, item 1
29 CFR 3314 C
Serious
$22,500
$18,000
Nov 22, 2005
Final
Citation 3, item 1
29 CFR 4002 A
Serious
$3,825
$315
Nov 22, 2005
Final
Citation 4, item 1
29 CFR 3999 B
Serious
$5,735
$315
Nov 22, 2005
Final
Inspection 301279998 OPENED AUG 20, 2004Closed
Accident · Partial · Safety · 700 employees at the site · Closed Apr 24, 2006
Incident on Jun 24, 2004: Employee's leg is fractured by falling slitter head
At approximately 7:00 a.m. on February 15, 2004, Employee #1, a maintenance mech anic, was operating a forklift, Yale walk behind lift, Model Number MCW030LAN24C S083, Serial Number N499290. He was hoisting a load when the slitter head slippe d off and fell on his right leg. He received a cut to his right thigh, a broken right knee, and a sprained left ankle. Employee #1 was hospitalized.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 1
29 CFR 3270 B
Other-than-serious
$315
$260
Dec 20, 2004
Final
Citation 2, item 1
29 CFR 3650 S12
Serious
$18,000
$18,000
Dec 20, 2004
Final
Inspection 301280004 OPENED AUG 20, 2004Closed
Accident · Partial · Safety · 700 employees at the site · Closed Apr 24, 2006
Incident on Feb 15, 2004: Employee fractures leg when slitter fall from forklift
At approximately 7:00 a.m. on February 15, 2004, an employee, a maintenance mech anic, suffered an injury when the forklift extension on the forklift, Yale walk behind lift, Model Number MCW030LAN24CS083, Serial Number 499290, he was using t o hoist a slitter head slipped off and the slitter head fell on his right leg. H e received a cut to his right thigh, a broken right knee, and a sprained left an kle. There were three other coworkers assisting the employee on this task. The e mployee was not hospitalized.
Incident on Oct 6, 2003: Employee's hand pulled into piston and two fingers amputated
At approximately 4:50 a.m. on October 6, 2003, an employee was cleaning the Grac o Pump at Line #3. He observed water on the pump and proceeded to wipe down the rim of the plunger with a paper towel. This is part of his normal job duties. Th e piston caught hold of the paper towel and pulled it into the machine along wit h his hand. The third and fourth fingers of his right hand were amputated but he was not hospitalized. There were no witnesses, but a coworker came upon the emp loyee right after the accident.
Incident on Jan 14, 2003: Employee hospitalized for treatment of amputated finger
At approximately 4:30 p.m. on January 14, 2003, an employee was operating a Dobo y wrapping Machine Number "b". As he was working, he noticed a problem with the wrapper on Machine "d". He was examining the problem when he placed his hand ove r the wrapper so that he could feel the position of the product underneath, as i t traveled on the conveyor. The employee became distracted when someone called o ut his name, and when he looked up, his hand accidentally contacted the reciproc ating blade that cut his fingers. The Doboy wrapping Machine Number "d" was in o peration while the point of operation guard was not in its proper position. The employee amputated his right index and middle fingers and was transported to USC medical center for emergency treatment.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 1
29 CFR 4548 B
Other-than-serious
$18,000
$850
Feb 28, 2003
Closed
Inspection 126091131 OPENED NOV 22, 2002Closed
Accident · Partial · Safety · 500 employees at the site · Closed Jul 15, 2008
Incident on Nov 22, 2002: Employee's arm fractured when caught in machine
At about 3:45 a.m. on November 21, 2002, Employee #1 was cleaning the conveyor b elt of the accu-cool rotor flow cooling conveyor, Model 1006-8-2, Serial Number 1015, which was located on Line 1. The conveyor belt was not very dirty, so he u sed a damp towel to clean the teflon-like surface. When Employee #1 finished cle aning the conveyor belt, his coworkers used a pressure hose to do some unrelated cleaning and got water on it. That caused a candy-like material to be transmitt ed from the rollers to the clean conveyor belt. Employee #1 grabbed a clean towe l and began cleaning the conveyor belt while it was running. During this time, t he sleeve of his coverall got caught in the upper roller and pulled his right ar m between the upper roller and the conveyor belt. A coworker heard Employee #1's screams and came to his aid. The coworker immediately pushed the stop button to stop the conveyor. Employee #1 had his arm all the way to the shoulder wedged b etween the upper roller and the conveyor belt. The coworker loosened the tension on the conveyor belt and removed Employee #1's injured arm. Employee #1 was tra nsported to the Foothill Presbyterian Hospital where he remained for six days wh ile being treated for five fractures of his right arm.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 1
29 CFR 3203 A
Other-than-serious
$850
$0
Mar 10, 2003
Final
Citation 2, item 1
29 CFR 3999 B
Other-than-serious
$5,735
$0
Mar 10, 2003
Final
Citation 3, item 1
29 CFR 3314 A
Serious
$18,000
$16,200
Mar 10, 2003
Final
Inspection 126091446 OPENED OCT 29, 2002Closed
Follow-up · Partial · Safety · 700 employees at the site · Closed Dec 27, 2002
Incident on Oct 28, 2002: Employee injured while cleaning horizontal mixer
At approximately 6:30 a.m. on October 28, 2002, Employee #1 and a coworker were cleaning a horizontal mixer. Employee #1 had only been working this job for two weeks and had not been provided training regarding proper lockout procedures whe n working on equipment. Employee #1 was using a small spatula to scrape the top and back of the mixer. Somehow, the coworker accidentally activated the mixer an d it began to operate in JOG. The mixer blade struck Employee #1's right arm and pulled him into the mixer. Employee #1 yelled for help and the coworker release d the JOG button, stopping the blade. Several coworkers responded, as well, assi sting to release Employee #1's arm from the shaft and provided first aid. Emerge ncy services were called and Employee #1 was transported to USC Medical Center, by helicopter. Employee #1 suffered and was treated for a partially severed and fractured forearm, damaged tendons and muscles, and radiating pain in his should er. He was hospitalized for 10 days.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 2, item 1
29 CFR 3314 A
Serious
$18,000
$18,000
Jan 3, 2003
Closed
Inspection 119822310 OPENED APR 4, 2001Closed
Accident · Complete · Safety · 450 employees at the site · Closed Apr 2, 2002
Incident on Mar 23, 2001: Employee loses tip of finger - nose bar pinched his fingers
At approximately 4:50 p.m. on March 23, 2001, Employee #1 lost the tip of his le ft index finger when the nose bar slipped out of his hand and pinched his finger between the bar and the kreuter enrover. Three witnesses observed the incident. The machine involved in the incident was the Line Number 5 kreuter enrover and the nose bar for the second tunnel conveyor. The nose bar and conveyor were supp orted by two pipes, one on each side near the enrover. A hydraulic jack or somet imes shims were used to compensate for the height difference between the nose ba r, conveyor and the kreuter enrover. This machine had been in operation for abou t three months when the incident occurred. At the time of the incident, Employee #1 and his coworker were aligning the Line Number 5 nose bar of the Number 2 tu nnel conveyor to the kreuter enrover. His coworker was aligning the pipe on one side of the machine using a pipe and a hydraulic jack. Employee #1 aligned the p ipe on the other side of the machine. Employee #1 placed the bottom of the pipe on top of some washers and shims, and the top of the pipe was placed under the c onveyor. Employee #1 attempted to hold the pipe in place with his right hand and lower the nose bar to the enrover with his left hand. The nose bar slipped out his hand and pinched his left index finger between the nose bar and the end of t he kreuter enrover. Coworkers applied pressure to the wound and escorted him to the office. Another coworker then drove Employee #1 to the local medical center. Employee #1 was transported to the Irwindale industrial clinic and later transf erred to the West Coast Orthopedic Medical Group were he was treated for amputat ion of the tip of his left index finger.
Incident on Jan 5, 1999: Employee's fingertip amputated in blender of melter machine
At approximately 5:00 p.m. on January 5, 1999, Employee #1, a temporary worker f rom Kelly Services assigned to the Nellson Nutraceutical Company, was cleaning m elter machine #3. He was clearing a jammed piece from the 4 in. diameter drain a t the bottom of the melter when his right middle finger struck against the blend er, amputating the tip. He was transported to the hospital, but the severed fing ertip could not be reattached. Employee #1 later stated in writing that he had n ot been trained or instructed on how to clean the melter, and that he was unawar e of the proximity of the blender to the drain he was clearing. He had been work ing at Nellson Nutraceuticals since October 1998.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 1
29 CFR 3203 B02
Other-than-serious
$375
$375
Jun 30, 1999
Closed
Citation 1, item 2
29 CFR 3203 A07
Other-than-serious
$375
$375
Jun 30, 1999
Closed
Citation 2, item 1
29 CFR 3314 F
Serious
$5,000
$5,000
Jun 30, 1999
Closed
Injury and illness logs
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Ontario site logged 5 recordable injuries or illnesses among about 400 workers: 1.0 per 100 full-time workers, against a median of 3.4 for its industry. Those cases cost 51 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Nellson Nutraceutical
Ontario · 2025
400
5
1
1.0
3.4
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
Alert subscribers get notified of each newly cited employer in California the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.