OSHA SearchOSHA records by employer

Nemorio Lopez Villegas: OSHA inspections and violations

Houston, Texas · Masonry Contractors · NAICS 238140

3inspections
4citation items
$17,199current penalties
Oct 7, 2020last inspection

Nemorio Lopez Villegas has 3 OSHA inspections on record in Texas, the first in 2016.

OSHA's last visit started on Oct 7, 2020 as a planned inspection, in Montgomery.

Across those inspections OSHA issued 4 citation items: 1 serious and 3 repeat.

OSHA proposed $31,682 in penalties. After settlements and reviews the total is $17,199, down 46%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Nemorio Lopez Villegas averages $8,600 over 2 cited inspections in that time.

Nemorio Lopez Villegas: OSHA citation items per year, 2016 to 2020
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Nemorio Lopez Villegas and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344964838 OPENED OCT 7, 2020Closed

Planned · Partial · Safety · 2 employees at the site · Closed Apr 28, 2023

20219 Eva Street, Montgomery, TX 77356 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Repeat$16,092$8,046Feb 4, 2021Final
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$6,437$3,218Feb 4, 2021Final
Citation 1, item 3
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Repeat$6,437$3,218Feb 4, 2021Final

Inspection 343783155 OPENED FEB 12, 2019Closed

Planned · Partial · Safety · 8 employees at the site · Closed Feb 14, 2019

3402 Houston Ave, Victoria, TX 77903 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341972297 OPENED DEC 13, 2016Closed

Planned · Partial · Safety · 6 employees at the site · Closed Oct 12, 2022

300 N. Loop W., Houston, TX 77008 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$2,716$2,716Feb 8, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(c)(2)

(2) Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured.

29 CFR 1926.453 · Aerial lifts

Other masonry contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.