Inspection 349275826 OPENED NOV 10, 2026Open
115 N 2nd St., River Falls, WI 54022 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
Since 2017, OSHA inspectors have visited Neo Electrical Solutions, LLC in Wisconsin 4 times.
The most recent inspection opened on Nov 10, 2026, in River Falls and is still open.
In all, OSHA issued 7 citation items: 4 serious and 3 other-than-serious.
The proposed penalties came to $8,278; today they stand at $5,794, 30% less.
The rule cited most here is 1926.405 (job-site wiring), 2 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Neo Electrical Solutions, LLC averages $1,931 across 3 cited inspections.
Neo Electrical Solutions, LLC also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Wisconsin · latest 90 days of OSHA records
231employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Wisconsin
Checking a subcontractor, a client or your own company? Watch Neo Electrical Solutions, LLC and get notified the morning OSHA posts a new citation for it.
Watch this company115 N 2nd St., River Falls, WI 54022 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
505 Pine Ridge Drive, Shell Lake, WI 54871 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.502(b)(1) · Fall protection systems |
Serious | $4,476 | $3,133 | Sep 30, 2021 | Final |
| Citation 1, item 1b 29 CFR 1926.1052(c)(1)(i) · Stairways in construction |
Serious | $0 | $0 | Sep 30, 2021 | Final |
1651 Hanley Road, Hudson, WI 54016 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1b 29 CFR 1926.405(g)(2)(iii) · Job-site wiring |
Other-than-serious | $0 | $0 | May 11, 2017 | Final |
| Citation 2, item 1 29 CFR 1926.405(a)(2)(ii)(i) · Job-site wiring |
Other-than-serious | $0 | $0 | May 11, 2017 | Final |
175 2nd Street S., Hudson, WI 54016 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.1052(c)(1)(i) · Stairways in construction |
Serious | $3,802 | $2,661 | May 9, 2017 | Final |
| Citation 1, item 1b 29 CFR 1926.1060(a) · Ladder and stairway training |
Serious | $0 | $0 | May 9, 2017 | Final |
| Citation 2, item 1 29 CFR 1926.1053(b)(16) · Ladders in construction |
Other-than-serious | $0 | $0 | May 9, 2017 | Final |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the Hudson site logged 5 recordable injuries or illnesses among about 85 workers: 6.7 per 100 full-time workers, against a median of 1.8 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Neo Electrical Solutions Hudson · 2024 | 85 | 5 | 0 | 6.7 | 1.8 |
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
Jul 11, 2025, Hudson: Hospitalization · fractures · pelvis
On July 11, 2025, at approximately 11:30 AM, an employee was on the fourth step of an 6-foot step ladder, manually pulling wire. He encountered resistance and the connection to the tape came loose. He lost his balance and fell to the floor, sustaining a fractured pelvis.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1053(b)(16)
(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.
29 CFR 1926.1060(a)
(a) The employer shall provide a training program for each employee using ladders and stairways, as necessary. The program shall enable each employee to recognize hazards related to ladders and stairways, and shall train each employee in the procedures to be followed to minimize these hazards.
Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.