Inspection 344798087 OPENED JUN 19, 2020Closed
1375 Capital Blvd., Reno, NV 89502 · Wired and Wireless Telecommunications Carriers (except Satellite) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Nevada Bell Telephone Company has 4 OSHA inspections on record in Nevada, the first in 1985.
OSHA's last visit started on Jun 19, 2020 after a complaint, in Reno.
Across those inspections OSHA issued 5 citation items: 5 other-than-serious.
OSHA proposed $3,750 in penalties. After settlements and reviews the total is $375, down 90%.
For context, across all media and telecom employers the median penalty per cited inspection since 2015 is $1,800. Nevada Bell Telephone Company averages $0 over 1 cited inspection in that time.
The Wage and Hour Division has 2 cases on it since 2015, with $0 in back wages owed to workers.
Nevada · latest 90 days of OSHA records
113employers cited
Get notified the morning OSHA posts each new citation in Nevada: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Nevada
Checking a subcontractor, a client or your own company? Watch Nevada Bell Telephone Company and get notified the morning OSHA posts a new citation for it.
Watch this company1375 Capital Blvd., Reno, NV 89502 · Wired and Wireless Telecommunications Carriers (except Satellite) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
645 E. Plumb Lane, Reno, NV 89502 · Telecommunications · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts |
Other-than-serious | $3,000 | $0 | Jun 23, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.36(g)(2) · Exit route design |
Other-than-serious | $0 | $0 | Jun 23, 2016 | Final |
1450 Vassar, Rm 101, Reno, NV 89520 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Other-than-serious | $750 | $375 | Aug 1, 1994 | Closed |
| Citation 2, item 1 29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jun 15, 1994 | Closed |
| Citation 2, item 2 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jun 15, 1994 | Closed |
100 N Center St, Reno, NV 89501 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.
| Period reviewed | Violations | Workers owed | Back wages | Penalties |
|---|---|---|---|---|
| Dec 29, 2016 to Jan 18, 2018 Reno | 3 | 0 | $0 | $0 |
| Nov 17, 2013 to Nov 16, 2015 Reno | 1 | 0 | $0 | $0 |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.219(c)(2)(i)
(2) Guarding horizontal shafting. (i) All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires.
29 CFR 1910.303(g)(1)(i)
(i) Working space for equipment likely to require examination, adjustment, servicing, or maintenance while energized shall comply with the following dimensions, except as required or permitted elsewhere in this subpart:
29 CFR 1910.36(g)(2)
(2) An exit access must be at least 28 inches (71.1 cm) wide at all points. Where there is only one exit access leading to an exit or exit discharge, the width of the exit and exit discharge must be at least equal to the width of the exit access.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.