It opened on Sep 11, 2018 after a complaint, in Brooklyn.

In all, OSHA issued 6 citation items: 6 serious.

The proposed penalties came to $21,595; today they stand at $12,500, 42% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. New Again Home Remodeling Corp. averages $12,500 across 1 cited inspection.

New Again Home Remodeling Corp.: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

360employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch New Again Home Remodeling Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343459319 OPENED SEP 11, 2018Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Jul 1, 2021

295 Stratford Rd, Brooklyn, NY 11218 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$1,705$1,305Feb 28, 2019Final
Citation 1, item 2
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$3,978$2,406Feb 28, 2019Final
Citation 1, item 4
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$3,978$2,406Feb 28, 2019Final
Citation 1, item 6
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$3,978$2,405Feb 28, 2019Final
Citation 1, item 7a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$3,978$3,978Feb 28, 2019Final
Citation 1, item 7b
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$3,978$0Feb 28, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)(ii)

(ii) Unstable objects shall not be used to support scaffolds or platform units.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(j)(2)

(2) Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.95 · Criteria for personal protective equipment