New American Painting, Inc.: OSHA inspections and violations

Riverview, Florida · Painting and Wall Covering Contractors · NAICS 238320

1inspections
5citation items
$3,260current penalties
Feb 7, 2017last inspection

OSHA inspectors have visited New American Painting, Inc. in Florida one time.

It opened on Feb 7, 2017 as a planned inspection, in Riverview.

In all, OSHA issued 5 citation items: 5 serious.

The proposed penalties came to $5,433; today they stand at $3,260, 40% less.

The rule cited most here is 1910.134 (respiratory protection), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. New American Painting, Inc. averages $3,260 across 1 cited inspection.

New American Painting, Inc.: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

316employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch New American Painting, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342083748 OPENED FEB 7, 2017Closed

Planned · Partial · Safety · 10 employees at the site · Closed Mar 8, 2018

10635 Laguna Plains, Riverview, FL 33568 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$1,630$978Feb 14, 2017Final
Citation 1, item 1b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Feb 14, 2017Final
Citation 1, item 1c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Feb 14, 2017Final
Citation 1, item 1d
29 CFR 1910.134(k)(1)(i) · Respiratory protection
Serious$0$0Feb 14, 2017Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,803$2,282Feb 14, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.134(f)(2)

(2) Deep breathing. In a normal standing position, the subject shall breathe slowly and deeply, taking caution so as not to hyperventilate.

29 CFR 1926.501 · Fall protection in construction

Other painting and wall covering contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.