Newman Associates: OSHA inspections and violations
Canton, Massachusetts · Fabricated Structural Metal Manufacturing · NAICS 332312
3inspections
10citation items
$13,171current penalties
Jan 23, 2023last inspection
OSHA has inspected Newman Associates 3 times in Massachusetts since 1993.
The latest one began on Jan 23, 2023 as a planned inspection, in Canton.
Those inspections ended with 10 citation items: 8 serious and 2 other-than-serious.
Penalties were first proposed at $23,153 and now stand at $13,171, 43% lower after settlements or reviews.
Hexavalent chromium comes up most often in these citations: 3 items under 1910.1026.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Newman Associates averages $6,586 (2 cited inspections).
Newman Associates also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Massachusetts · latest 90 days of OSHA records
247employers cited
Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2021, the Canton site logged 2 recordable injuries or illnesses among about 42 workers: 4.1 per 100 full-time workers, against a median of 1.7 for its industry. Those cases cost 76 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Newman Associates, LLC
Canton · 2021
42
2
2
4.1
1.7
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(c) Permissible exposure limit (PEL). The employer shall ensure that no employee is exposed to an airborne concentration of chromium (VI) in excess of 5 micrograms per cubic meter of air (5 µgm/m 3), calculated as an 8-hour time-weighted average (TWA).
29 CFR 1910.1026(f)(1)(i)
(f) Methods of compliance—(1) Engineering and work practice controls. (i) Except as permitted in paragraph (f)(1)(ii) and paragraph (f)(1)(iii) of this section, the employer shall use engineering and work practice controls to reduce and maintain employee exposure to chromium (VI) to or below the PEL unless the employer can demonstrate that such controls are not feasible. Wherever feasible engineering and work practice controls are not sufficient to reduce employee exposure to or below the PEL, the employer shall use them to reduce employee exposure to the lowest levels achievable, and shall supplement them by the use of respiratory protection that complies with the requirements of paragraph (g) of this section.
29 CFR 1910.1026(g)(2)
(2) Respiratory protection program. Where respirator use is required by this section, the employer shall institute a respiratory protection program in accordance with § 1910.134, which covers each employee required to use a respirator.
Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.