OSHA SearchOSHA records by employer

Nexcivil Engineering and Construction LLC: OSHA inspections and violations

Aurora, Colorado · Engineering Services · NAICS 541330

1inspections
3citation items
$8,300current penalties
Sep 9, 2024last inspection

Nexcivil Engineering and Construction LLC has one OSHA inspection on record in Colorado.

OSHA opened it on Sep 9, 2024 after a complaint, in Aurora, and the case has not closed yet.

From that inspection OSHA issued 3 citation items: 3 other-than-serious.

OSHA proposed $11,062 in penalties. After settlements and reviews the total is $8,300, down 25%.

Most often, OSHA cited 1926.652, trench protection (3 items).

For context, across all professional services employers the median penalty per cited inspection since 2015 is $1,820. Nexcivil Engineering and Construction LLC averages $8,300 over 1 cited inspection in that time.

Nexcivil Engineering and Construction LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

139employers cited

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Nexcivil Engineering and Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347740722 OPENED SEP 9, 2024Open

Complaint · Partial · Safety · 4 employees at the site · Open

1198 S Havana St, Aurora, CO 80012 · Engineering Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.652(a)(1) · Trench protection
Other-than-serious$6,452$4,850Dec 2, 2024Final
Citation 1, item 1b
29 CFR 1926.652(g)(2) · Trench protection
Other-than-serious$0$0Dec 2, 2024Final
Citation 1, item 2
29 CFR 1926.652(g)(1)(iii) · Trench protection
Other-than-serious$4,610$3,450Dec 2, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(a)(1)

(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:

29 CFR 1926.652(g)(1)(iii)

(iii) Employees shall be protected from the hazard of cave-ins when entering or exiting the areas protected by shields.

29 CFR 1926.652(g)(2)

(2) Additional requirement for shield systems used in trench excavations. Excavations of earth material to a level not greater than 2 feet (.61 m) below the bottom of a shield shall be permitted, but only if the shield is designed to resist the forces calculated for the full depth of the trench, and there are no indications while the trench is open of a possible loss of soil from behind or below the bottom of the shield.