Inspection 343275111 OPENED JUL 5, 2018Closed
351 Riverside Dr, New York, NY 10025 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Next Generatiion Construction LLC has 2 OSHA inspections on record in New York, the first in 2017.
OSHA's last visit started on Jul 5, 2018 to follow up on an earlier case, in New York.
Across those inspections OSHA issued 2 citation items: 2 serious.
OSHA proposed $7,243 in penalties and the amount has not been reduced.
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Next Generatiion Construction LLC averages $7,243 over 1 cited inspection in that time.
New York · latest 90 days of OSHA records
362employers cited
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Next Generatiion Construction LLC and get notified the morning OSHA posts a new citation for it.
Watch this company351 Riverside Dr, New York, NY 10025 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
351 Riverside Dr, New York, NY 10025 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.403(b)(1)(i) · Electrical equipment on job sites |
Serious | $4,346 | $4,346 | May 23, 2017 | Final |
| Citation 1, item 2 29 CFR 1926.350(a)(10) · Gas welding and cutting |
Serious | $2,897 | $2,897 | May 23, 2017 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.350(a)(10)
(10) Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.
29 CFR 1926.403(b)(1)(i)
(i) Suitability for installation and use in conformity with the provisions of this subpart. Suitability of equipment for an identified purpose may be evidenced by listing, labeling, or certification for that identified purpose.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.