Inspection 346076268 OPENED JUL 13, 2022Closed
660 Cornerstone Dr., Kissimmee, FL 34744 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Saint Cloud, Florida · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116
Next Level Builders, LLC has 2 OSHA inspections on record in Florida, the first in 2021.
OSHA's last visit started on Jul 13, 2022 as part of a related case, in Kissimmee.
Across those inspections OSHA issued 3 citation items: 3 serious.
OSHA proposed $8,193 in penalties. After settlements and reviews the total is $6,028, down 26%.
Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,079. Next Level Builders, LLC averages $6,028 over 1 cited inspection in that time.
Want to know if OSHA cites Next Level Builders, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company660 Cornerstone Dr., Kissimmee, FL 34744 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4775 Pine Tree Dr., Saint Cloud, FL 34772 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(c)(1) · Scaffolds, general requirements |
Serious | $2,926 | $2,194 | Dec 2, 2021 | Final |
| Citation 1, item 2 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $2,341 | $1,639 | Dec 2, 2021 | Final |
| Citation 1, item 3 29 CFR 1926.451(g)(1) · Scaffolds, general requirements |
Serious | $2,926 | $2,194 | Dec 2, 2021 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(c)(1)
(c) Criteria for supported scaffolds. (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:
29 CFR 1926.451(e)(1)
(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.
29 CFR 1926.451(g)(1)
(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.